Problem
Water flows on the
rear plate of the re-
frigerator.
Water flows into the
refrigerator.
Water flows on the
ground.
The temperature in
the appliance is too
low.
The temperature in
the appliance is too
high.

6.1 Replacing the lamp

Possible cause
The door is not closed
correctly.
The door has been
opened too frequently.
The product temperature
is too high.
The room temperature is
too high.
During the automatic de-
frosting process, frost de-
frosts on the rear plate.
The water outlet is clog-
ged.
Products prevent that wa-
ter flows into the water
collector.
The melting water outlet
does not flow in the evap-
orative tray above the
compressor.
The temperature regulator
is not set correctly.
The temperature regulator
is not set correctly.
1.
2.
3.
4.
5.
6.
7.
8.
Solution
Refer to "Closing the door".
Do not keep the door open
longer than necessary.
Let the product tempera-
ture decrease to room tem-
perature before storage.
Decrease the room temper-
ature.
This is correct.
Clean the water outlet.
Make sure that products do
not touch the rear plate.
Attach the melting water
outlet to the evaporative
tray.
Set a higher temperature.
Set a lower temperature.
Disconnect the mains plug from the
mains socket.
Remove the screw from the lamp
cover.
Remove the lamp cover (refer to the
illustration).
Replace the used lamp with a new
lamp of the same power and specifi-
cally designed for household applian-
ces. (the maximum power is shown
on the lamp cover).
Install the lamp cover.
Tighten the screw to the lamp cover.
Connect the mains plug to the mains
socket.
Open the door. Make sure that the
lamp comes on.