5
TROUBLESHOOTING
5
TROUBLESHOOTING
5.1
GENERAL________________________________________________________________
The troubleshooting chart below lists basic problems that may occur during start-up and operation. For more detailed
information regarding the hydraulic and electrical systems contact your area Jacobsen Dealer.
Symptoms
Engine will not start.
Engine hard to start or
runs poorly.
Engine stops.
Engine overheating
Battery not holding
charge.
Tractor does not react
to traction pedal
Implement does not
raise or lower
Gauges/Indicator
not
operating
GB-20
Possible Causes
1.
Parking brake disengaged,
traction pedal not in neutral.
2.
Battery low on charge or
defective.
3.
Fuel tank empty or dirty. Fuel shut
off valve closed
4.
Circuit breaker blown.
1.
Fuel level low, fuel or fuel filter
dirty.
2.
Air cleaner dirty.
3.
Injectors, fuel pump
4.
Engine problem.
1.
Fuel tank empty.
2.
Interlocks not set before leaving
operator's seat.
1.
Coolant level low.(Diesel)
2.
Air intake restricted.
3.
Water pump belt broken or
loose.(Diesel)
4.
Engine overload
1.
Loose or corroded battery
terminals.
2.
Low electrolyte.
3.
Alternator belt loose or broken.
4.
Charging system defective.
1.
Parking brake engaged
2.
Tow Valve Open
3.
Low hydraulic oil
1.
Low hydraulic oil
1.
Fuse blown
2.
Loose wiring
Action
1.
Check Interlock System and start-up procedure.
2.
Inspect condition of battery and battery connections.
3.
Fill with fresh fuel. Change fuel filter. Bleed fuel lines.
Open fuel shut off valve
4.
Reset circuit breaker.
1.
Fill with fresh fuel. Change fuel filter. Bleed fuel lines.
2.
Inspect and replace air filter.
3.
Consult engine manual.
4.
Consult engine manual
1.
Fill with fresh fuel and bleed fuel lines.
2.
Engage parking brake and traction pedal in neutral.
1.
Inspect and add coolant.
2.
Clean cooling air intake.
3.
Tighten or replace belt.
4.
Reduce forward speed
1.
Inspect and clean terminals
2.
Refill to correct level.
3.
Tighten or replace belt
4.
See engine manual
Disengage parking brake.
Close Tow Valve
Check reservoir level and fill if needed
Check reservoir level and fill as needed
Replace fuse, check bulb
Check electrical connections.