Zivan NG3 Manual De Uso E Instalación página 21

Ocultar thumbs Ver también para NG3:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 42
ADDITIONAL FEATURES WITH AIR PUMP
Operation principle
Standard Version
The Air Pump technology generates a re-mix of the acid inside the battery by a constant delivery of air
pumping.
The battery charger controls the air pump by an auxiliary contact (generally AUX1).
An air injection cycle along all the charging period is held as per requirements of the battery
specifications.
Pressure sensor version
Further to the characteristics of the standard version it is also available an electronic circuit equipped with
an air pressure sensor.
At the beginning of the charging process, the sensor verifies that the pressure in the circuit is included in
a definite window between a minimum and a maximum value (look at the following table). When an
anomaly occurs the battery charger will modify the charging factor by effecting a charge without detecting
and controlling the Air Pump
Technical Features
Description
Power absorbed by the Air Pump
Input fuse
Maximal dimensions
Weight
Air Delivery*
Available pressure range
* To know the effective air delivery please refer to the plate values
D01058-08
Battery charger NG3
Symbol
Test Condition
P
Air Pump controlled
ap
-
Equipment interns
a×b×c
Without connecting cables 540×227×201
-
Without connecting
cables
Q
Air Pump controlled
Starting charging point
∆p
English
Value and/or
Unit
Range
90
W
1,6
A
mm
10,5
kg
4÷13
l/min
50÷250
mbar
21