Fig. 9:
Pressure sensor installation
4. Insert the sealing cone (see Fig. 9, item 2) into the
adapter's pressure sensor mount (item 3).
5. Screw the pressure sensor (item 1) into the
adapter's pressure sensor mount.
6. Tighten the pressure sensor by the adapter's hex
nut (see Fig. 10).
Tightening torque: 20 ± 2 Nm.
Fig. 10:
Tightening pressure sensor
Robert Bosch GmbH
4.3
1. Clamp the injectors.
2. Select the appropriate adapter nut (item 2).
3. Screw the adapter nut onto the adapter (item 1),
4. Connect the adapter to the high-pressure inlet of
Fig. 11:
5. Connect the test pressure line or high-pressure
i
6. Make the hydraulic and electrical connections for
4.4
i
¶
20 ±2 Nm
Preparation for testing | CRI/CRIN SST | 23 |
Connecting the adapter
and tighten it.
the injector (item 3).
Tightening torque: 25–30 Nm.
1
2
Adapter installation
hose assembly to the adapter.
Tightening torque: 25–30 Nm.
The operating instructions for tester set CRI/
CRIN 848H describe the connection of injectors.
the injectors.
Connecting the pressure sensor
When connecting the pressure sensor to the
CRI 800 actuation electronics, make sure to comply
with the channel assignments (injector A to channel
A etc.).
Use connecting cable 1 684 465 868 to connect
the pressure sensor to the sockets for the pressure
sensor on the CRI 800 actuation electronics (see
fig. 2, item 3).