7.
Troubleshooting
7.1
Error messages
System faults are indicated by error messages on the screen.
2054 CRI UBAT too low
Example:
Use <F12> to delete the error message. If the cause for the error has not been resolved, the error message will
be displayed again during operation.
The following table lists all the error messages and remedial measures that might occur during the testing of
common-rail injectors. If the fault cannot be resolved, contact Bosch customer service.
i
If you direct a query to customer service relating to a fault, specify the status code and module ID so the
fault can be resolved quickly.
Status
Module
Error message
code
ID
No data received from module
34
SST
Excessive variation in pressure
61
SST
Algorithm unidentifiable
104
SST
Minimum identified before injection Hydraulic fault: repeat measurement.
1000
SST
Software components missing
1001
SST
No pressure curve data received
1002
SST
Pressure curves incomplete
2041
SST
Power supply for pressure sensor X Check the electrical connector for pressure sensor X.
2042
2043
2044
2045
2046
2047
SST
Internal SST voltage supply
2048
SST
Voltage supply
2051
2053
2054
2055
2052
SST
Voltage supply 13 V
2057
SST
No CRI 800 trigger signal
7.2
Symptoms
Symptom
The shot-to-shot scatter measurements are not being
performed.
Robert Bosch GmbH
Troubleshooting | CRI/CRIN SST | 25 |
Remedial measures
Check the USB cable.
Check the voltage supply.
Check all electrical connectors of the pressure sensor.
Check the hydraulic connections for leaks.
Rest the zero point on all pressure sensors (see section 8.1).
Inform customer service.
Hydraulic fault: repeat measurement. If the issue persists, the injector
is defective.
Software error. Re-install the EPS 945 system software.
Check the electrical cables. Repeat measurement.
Repeat measurement.
Check the internal connections in the actuation electronics.
Check the power supply at the voltage stabilizer. If necessary, set it to
14 V or 28 V respectively.
Switch the voltage stabilizer off and on again.
Inform customer service.
Check the electrical connector for pressure sensor X.
Check the internal connections in the actuation electronics.
Check the internal connections in the actuation electronics.
Remedial measures
Check if automatic mode has been activated for the test.
Check if the SST injection monitor has been activated in the configuration.
Check if the Q3S setpoint has been entered in the test sequence.
Check if setpoints have been entered for the quantities in the test
sequence.
en
|
1 689 989 098
2021-02-24