Paragraph 3 – Timed Dosage (Frequency signal input "TRIGGER" activated)
Programming
PROG
Configuration
Configuration
Pump functions
-
+
Pump functions
Time
Time
-
Quantity
100ml
Time
g.hh.mm
-
Delay
0.01.50
Time
g.hh.mm
-
interv.
0.01.50
Trigger Mode
-
N. Open
Pause Input Mode
-
Trigger Mode
Display during Operation
Operating mode
Timer
Alarms and statuses
Liv = level alarm
Flow = flow alarm or
....Release wait
Pos: 78 /Alle Produkte/Dummy_module/===== Seitenwechsel ===== @ 0\mod_1125648978015_0.doc @ 1631 @
All manuals and user guides at all-guides.com
-
+
-
+
-
+
Trigger Mode
-
N. Open
Trigger Mode
-
N. Closed
Trigger Mode
Disable
FLOW
Programmed value
sensor status
Quantity in ml
Timer
F
F F
7,0 ml
Stop
P 0%
Value of the dosing in
progress
Pump status
Dry = pump starting up
Stop = pump stop
Restart = pump restart
Operation
After receipt of the TRIGGER signal set, the pump doses a quantity
that can be programmed in ml. It is possible to set a delay time
before the dosing (Delay) and the interval between subsequent
dosings (Interv.) as illustrated in the diagram:
Trigger
Delay
By setting for example an Interval. time = 0, a system is obtained in
which the programmed quantity is dosed after each TRIGGER
signal (with any delay that has been set):
Trigger
Delay
It is possible to start the dosing by pressing the + key, which, in
practice, simulates the Trigger signal.
The Trigger signal can be set to N. Open (it is activated when the
input passes from the open to the closed mode) or to N. Closed (it
is activated when the input passes from the closed to the open
mode).
The Trigger signal is locked during dosing (its receipt is neither
stored nor managed).
The Pause (Remote input) input cannot be programmed and its
activation stops the dosing, while its further deactivation makes the
system wait again for the Trigger signal for a new dosing.
The dosage frequency can be modified while the pump is operating,
by pressing the
frequency, or the
Display during Setting (MODE key)
The following are shown in sequence:
quantity to dose, delay in d.hh.mm.
and interval in d.hh.mm
Q.tà
20,0ml
Percentage of
strokes/min
max
Value of the dosing percentage,
which can be modified by
pressing the + or – keys
Quantity
Interv.
Release
Ritardo
keys at the same time to increase the
keys to decrease it.
Operating mode
Dosing value
Programmed
20,0ml
P 100%
quantity in m
- GB -