Instruction Setting
23.1
Functions:
Calibration (Press Cal Key
►
Select the calibration routine pH or Redox by Up or Down key.
Standard Routine calibration pH probe is 7 and 4 buffer solution and Redox 465 mV buffer solution
Set Point (Press Set Key
►
Press Set Key and choose SetPoint and adjust value with Up or Down Key before press Enter and
confirm.
Sp_750mv___700_mv_
−
Sp_7.4ph____7.6_ph_
−
Press Cal and Set Key (both)
►
23.2
Program_Menu (Press Enter to set the following Item)
Language_ (It's possible to have 5 language EN, IT, SP, DE, FR)
►
Redox_Measure
►
setpoint___750_mv (Adjust value with enter and up or down key) It's possible to adjust from
−
0 to 1000 mV value for Redox
sp_type___low (Adjust value LOW or HIGH)
−
ofa_time_000_min (Adjust value OFF or set Time)
−
alarm_band__000_rx (Adjust value from 100 to 300 mV )
−
ph_Measure
►
setpoint____7.4ph (Adjust value with enter and up or down key) It's possible to adjust from 0
−
to 14 pH value.
sp_type___acid (Adjust value ACID or ALKA)
−
ofa_time_000_min (Adjust value OFF or set Time)
−
alr_band__000_ph (Adjust value from 1 pH to 3 pH)
−
Temp__25*C_(Adjust value with enter and up or down key) pH measure only.
−
Flow_(Adjust value with enter and up or down key Enable or Disable)
►
It's possible to enable(ON) or disable (OFF) signal input
−
Calibration_probe (Adjust value with enter and up or down key)
►
Full (pH 7 and 4, Redox 465 mV buffer solution)
−
Easy (pH 7, Redox 465 mV buffer solution)
−
Off (Disabled)
−
Password (Adjust value with enter and up or down key, standard value 0000)
►
23.3
Exit______save
(Adjust value with up or down key and confirm with enter key)
►
Save and escape Program setup with ESC key
►
23.4
priming_____700mv
Priming Pump Keep Press UP Key for 1 seconds
►
23.5
priming_____7.2ph
Priming Pump Keep Press Down Key for 1 seconds
►