- GB -
Pos: 112 /Gartentechnik/KDS Anlage INVIKTA/Alarm INVIKTA @ 12\mod_1253712462689_121.doc @ 75826 @
28.
Alarm
Alarm
Level
OFA First Alarm (time >70%)
OFA Second Alarm (time
=100%)
Flow Rate
System Error
Calibration Function
29.
Default parameters:
Language = UK
►
Set Point value= 7,4 pH; 750 mV (Rx)
►
Dosing Method = Acid; Low (Rx)
►
Time OFA = OFF
►
Calibration = Full
►
Flow Input= OFF
►
30.
To restore Default parameters run Following steps:
Power off Pool Basic unit
►
Keeping Press UP and DOWN Key switch on the Power.
►
The unit will flash Init.default__no
►
Press up Init.default__Yes
►
Enter Key to restore Default parameters.
►
Pos: 113 /Alle Produkte/Überschriften/H1 Entsorgung @ 7\mod_1196625583904_121.doc @ 41547 @
31.
Disposal
Pos: 114 /Alle Produkte/Entsorgung/ENT BAS - Kein Hausmüll @ 10\mod_1243521970991_121.doc @ 63330 @
Do not dispose of this unit with domestic waste! For disposal purposes, please use the return
system provided. Disable the unit beforehand by cutting off the cables.
Pos: 115 /Alle Produkte/Dummy_module/===== Seitenwechsel ===== @ 0\mod_1125648978015_0.doc @ 1631 @
40
All manuals and user guides at all-guides.com
Display
level____7,2_ph
ofa_alarm__7,2_ph
ofa_stop___7,2_ph
Flow_______7,2_ph
Parameter_error
Error_7_ph Error_4_ph
Error_465_mv
Relais
Alarm Relay Close
Alarm Relay open
Alarm Relay Close
Alarm Relay open
Alarm Relay Open
Alarm Relais geöffnet
Abhilfe
Push Enter Key to open Alarm
−
Relay
Restore Product tank
−
Push Enter Key to reset
−
Push Enter Key to reset
−
Restore Flow Rate
−
Press Enter Key to replace
−
Default parameter
Destroy Unit
−
Restore Probe or Buffer
−
solution and repeat calibration
function