Force limits
Flange,
Type
DN [mm]
25/32
1s-5
40
10
50
15 and 20
65
32
80
45
100
64 and 90
125/150
120 and 150
Torque limits
Flange,
Type
DN [mm]
25/32
1s-5
40
10
50
15 and 20
65
32
80
45
100
64 and 90
125/150
120 and 150
3.1.8 Positioning the terminal box
You can turn the terminal box to four positions, in
90 ° steps. Follow this procedure:
1. If necessary, remove the coupling guards. Do not
remove the coupling.
2. Remove the bolts securing the motor to the
pump.
3. Turn the motor to the required position.
4. Replace and tighten the bolts.
5. Replace the coupling guards.
Carry out the electrical connection as shown in the
diagram inside the terminal box cover.
CR -
Cast iron pump housing
Force, Y-
Force, Z-
direction
direction
[N]
[N]
338
394
413
469
563
581
694
788
938
769
1256
1013
1256
1013
CR -
Cast iron pump housing
Torque, Y-
Torque, Z-
direction
direction
[Nm]
[Nm]
300
175
400
275
450
325
500
350
325
400
375
475
375
475
Stainless steel pump housing
Force, X-
Force, Y-
direction
direction
[N]
[N]
319
675
375
825
506
1125
638
1388
844
1875
1125
2513
1125
2513
Stainless steel pump housing
Torque, X-
Torque, Y-
direction
direction
[Nm]
[Nm]
125
600
200
800
250
900
300
1000
550
650
625
750
625
750
CRI, CRN -
Force, Z-
Force, X-
direction
direction
[N]
[N]
788
638
938
750
1163
1013
1575
1275
1538
1688
2025
2250
2025
2250
CRI, CRN -
Torque, Z-
Torque, X-
direction
direction
[Nm]
[Nm]
350
250
550
400
650
500
700
600
800
1100
950
1250
950
1250
9