THERMOTECHNICAL CHARACTERISTICS
Hopper capacity
Efficiency
Available power
Autonomy (min/max)
Fuel consumption (min/max)
Heatable volume*
Weight including packaging
Smoke duct diameter
Air intake pipe diameter
* The heatable room dimensions are calculated on the basis of
pellets with an lhv of at least 4300 kcal/kg and home insulation in
compliance with Italian law 10/91, and subsequent changes toge-
ther with an expected heat output of 35 Kcal/m³ per hour.
* It is also important to consider the position of the stove in the
room to be heated.
N.B.
1) bear in mind that external devices may cause interference.
2) caution: live parts. Servicing and/or inspections must be carried out by qualified staff.
(Before carrying out any maintenance, disconnect the device from the mains power supply)
ELECTRICAL CHARACTERISTICS
Power supply
On/off switch
Average power consumption
Power consumption during ignition
Remote control frequency (optional)
Protection on mains power supply *
Protection on electronic circuit board
SAFETY DEVICES:
THERMOCOUPLE:
placed at the smoke outlet to detect the temperature.
Turns the stove on and off and controls its operation based on
defined parameters.
AIR FLOW SENSOR:
installed at the intake duct, it trips when the combustion air fl ow is
not correct, causing low pressure problems in the smoke circuit.
SAFETY THERMOSTAT:
trips when the temperature inside the stove is too high.
It stops pellet loading, causing the stove to shut down.
* *
15
90,1
5,8
11/30
0,5/1,4
145
143
80
40
230Vac +/- 10% 50 Hz
Yes
150
400
Infrared
2A, 250 Vac Fuse 5x20
2A, 250 Vac Fuse 5x20
FUSE
* two fuses are inserted on the socket
behind the stove, fitted with a switch one
is functional and the other is spare.
kg
%
kW
hours
kg/h
m3
kg
mm
mm
SMOKE
SPEED
W
W
FLOW
SENSOR
SMOKE EXTRACTION
MOTOR
SERIAL PORT
The Dealer can install an optional
on the AUX outlet (clean contact
on the pins) for controlling the
process of switching on and off (e.g. telephone remote,
local thermostat), located at the rear oh the stove. Can
be connected via special optional trestle (code 620550).
BACKUP BATTERY
A backup battery is found on the control board (3-Volt
CR 2032 battery).
Its malfunction is indicated with the following messages:
(not considered a defect but due to normal wear-and-
tear): ERR 1 - ERR 2.
For more detailed information, please contact the DEA-
LER who has performed the first 1st ignition.
- 16
-
THERMOCOUPLE
P/TEMP.
ADJUSTMENT
ROOM
SENSOR
BACKUP
BATTERY
MAINS
SCREW FEEDER
MOTOR
VENTILATION
IGNITION HEATING
ELEMENT
SAFETY
THERMOSTAT
Connessioni cavo combinato
pin 7
Pin 6 e pin 7
VENTILATION
ADJUSTMENT
pin 6
620550