c) The conduit should not come to an end near buildings and must be higher than the nearest obstacle if
there is another building nearby.
Incorrect
d) Install the conduit in an area as protected from the cold as possible. If possible, the chimney should
be built inside the house.
e) The internal walls must be perfectly smooth and free from obstacles. Avoid bottlenecks where pipes
join to the brick chimneys.
Incorrect
f) It is very important to ensure that the joints of the pipes are well sealed to avoid possible cracks
through which air may enter.
Without
Seal
INCORRECT
g) In order to verify the air-tightness of the chimney, you may:
-
Cover the outlet on the roof.
-
Introduce damp paper and straw at the bottom of the chimney
and light it up.
-
Watch for possible cracks through which smoke leaks out and
seal them.
Fig.-4
Correct
Fig.-5
Sealed
CORRECT
Fig.-6
Incorrect
INCORRECT
28
Correct
Correct