The advantage of using compact equipment is that installation is minimum. An electrical outlet and two drains
are all that is needed. The compact filtration unit meets standard UNE 20-460-93. Under no circumstances will
the manufacturer be held responsible for the assembly, installation or start-up of any incorporation of electrical
components that has not taken place on its premises
3. INSTALLATION AND ASSEMBLY
All electrical installations should comply with the following standard:
EN 60335-2-41, safety of household or similar electrical appliances, particular requirements for pumps
As such with all rules pertaining to "to the construction of electrical installations within specific confines: swimming
pools and fountains", or the equivalent standard in force in each region or country.
•
This equipment should be installed in pools with a maximum depth of 1.5 m.
•
Do not submerge the equipment or put it in a place where it could be submerged.
•
It is recommended that the filtration box is not drilled as water in the ground could penetrate through any
underground holes.
To install the unit, follow the steps below:
3.1. INSTALLATION OF THE COMBO FRONT MODULE
•
Place the Combo in the most suitable position bearing in mind the direction of prevailing wind. The front
module of the Combo should be located in the area where dirt accumulates (leaves and other floating particles),
meaning that it should be placed centrally on the wall which is against the direction of the prevailing wind (fig.
5).
•
Having decided on the most suitable position for the front module, the wall should be prepared for
installation. In a new pool, plan to leave the crown with the conditions specified below; if the installation is to be
made in a completed pool, part of the crown will have to be removed to provide the following specifications:
•
Part of the pool wall should be left free from the crown (82 cm), so that the front module and its fairing
can be incorporated. The water level of the pool should cover half the hinged gate of the skimmer. (It is
recommended that a distance of 15 cm is left between the water level and the base where the front module
rests) (fig. 6). The surface on which the equipment rests should be completely horizontal and flat so that the
equipment is exactly aligned to the wall.
•
Place the front module of the Combo in the cavity of the crown so that it rests on the pool wall and is
vertically aligned to the wall. Mark on the upper part of the wall where the drill holes should be made to secure
the equipment (fig. 7).
Note: the front module should rest on the rubber pads.
Remove the front module from the wall and make 2 drill holes for the plugs supplied. Clean the surface, put the
plugs and rubber pads supplied in place and reassemble the front module in its final position. Secure using DIN
571 M8x50 screws and their corresponding washers (supplied) (fig. 7).
3.2. INSTALLATION OF THE FILTRATION BOX
•
The filtration box can be joined directly to the front module (fig. 8-A) or aligned at a certain distance (fig.
8-B). If the decision is made to join the two modules, they should be placed in such a way that the hinged cover
of the filtration box falls onto the front module and closes it. In order to install the modules together, the wall of
the swimming pool should not be more than 22 cm thick; for greater thicknesses, the equipment will have to be
installed separately with their corresponding seal fairings. Mark on the ground the area where the filtration box is
to be placed. Normally it is aligned with the front module. If the box is located at a distance greater than 3.5 m
from the front module, terminal boxes should be used for the light cable. For easy connection of the drain and
other conduits, a hole should be dug allowing 25 cm around the whole of the filtration box in order to connect
the drains and for subsequent refilling.
•
The hole should be dug to a depth of 44 cm. Channels should also be made for the supply of running
water, drains and electrical power up to the position of the filtration box. If the filtration box is not joined directly
All manuals and user guides at all-guides.com
.
European Low Voltage Directive 2006/95/CE,
4