4. LCD Display Icons

4.1 The button
1. SET/OK: Setting button, enter button.
2. UP: Setting button ﹙UP﹚.
3. DOWN: Setting button ﹙DOWN﹚.
4. MENU/ESC: Menu button, exit button.
5. ON/OFF: Power on/off switch.
4.2 The normal display
BA TT
1
2 3
v
Noted:
• Press ''ESC'' to select the indication of the Icon 3 ﹙Output voltage, current, power, frequency﹚ Press "Up" to select or set auto
switch the data of Icon 3.
• Press and hold "UP" and "DOWM" button 3S at the same time until the display backlight flashes 3 times and the data parameters
are restored to the factory default values;
• When no fault , the LCD screen backlight automatically turns off when the button is not operated for 30s. When there is a fault or
touch the button, the LCD screen automatically lights up.
4.3 The fault display
02
5 1
6
BA TT
v
When faults occur: the Icon 2
indicate the corresponding code,
and the flashing with warning code,
the LCD screen backlight is always lit.
4.4 The setting interface
01
0 1
5
BA TT
v
Noted
Undervoltage warning value = undervoltage closing value + 0.5V,
overvoltage warning value = overvoltage closing value - 0.5V.
OU TP UT
NO
1
23 4
v
1
~
2
100%
3
4
5
6
000
OU TP UT
Fault
!
v
ERROR
Battery low voltage
Battery over voltage
~
Front-end circuit over temperature
100%
Back-end circuit over temperature
Front and backend over temperature
Output overload
Output short circuit
Long press "SET/OK" for 5s, enter the setting interface as shown above, while Icon 1, Icon
3 flashing settings parameters, Icon 2 flashing settings interface code;
Press "UP" and "DOWN" to adjust parameters, then press "SET/OK" to confirm the
adjustment.
If re-set the parameter, short press "SET" to make Icon 1 flashing;
~
Pressing the "ESC" to cancel this step and switch to next setting interface directly.
100%
Long press "ESC" for 5s, exit setting interface to the main interface; more than 10s
without any operation,the interface will automatically return to the main interface.
BA TT
OU TP UT
3. 1
2
1
23 4
v
v
~
100%
POWER
FAULT
SET
MENU
ON
OK
ESC
OFF
UP
DOWN
Icon
Function description
BA TT
1
2 3
Indicate battery output voltage
v
N
O
Indicate the setting programs or warning and fault codes
1
﹙When the product runs normally: the icon rotates clockwise;
when the product fails, display the fault codes.﹚
OU TP UT
23 4
Indicate output voltage, current, power, frequency
v
Indicate battery level
~
DC/AC inverter working
100%
Indicate the percentage of load level
- 14 -
Code
01
02
03
04
05
08
09