DITEC NRG100TXE Manual Tecnico página 12

Automatizaciones para puertas seccionales industriales
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 27
5. CHAIN LINK-UP INSTALLATION
NRGCTR1 (ratio 1:1)
NRGCTR15 (ratio 1:1,5)
NRGCTR2 (ratio 1:2)
NRGCAB
EL400
EL500E
5.1 INSTALLATION
ATTENTION! firmly tighten down all fastening screws.
- After having determined the position of the wall bracket, drill the holes and secure the bracket in place with dowels (not included)
- Fit the crown wheel onto the sectional door shaft and insert the appropriate cotter depending on shaft cavity length
metal clamp
so as to prevent the risk of the cotter coming out of the shaft.
- Link up crown and pinion by means of the chain. Properly tauten the chain by acting on the wall anchoring brackets. Fix the bracket
to avoid that the shaft of the sectional bends and to guarantee the correct tensioning of the chain.
EN
NRG100TXE
NRG100TRE
NRG100TXF
NRG140TXE
6.35 (1/4")
12
. Fasten the
6.35
(1/4")
9.5
(3/8")
.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Nrg100treNrg100txfNrg140txe

Tabla de contenido