Track replacement
Follow the instructions above to refit the rotor and pumphead guard. Refitting the track is the
l
reverse of removal
Test the electrical resistance between the latch and motor, the resistance must be <1MΩ
l
1.
It is imperative that the 620 pumpheads are earthed by connecting
the earth terminal on the track to earth (usually via a suitable point
on the pump drive).