Page 2: Counters
Hour Meters indicate the hours that: the controller has been powered up,
and the compressor has been running.
Starts indicate the number of times a start is attempted on the
compressor.
Date & Time is adjustable and configurable in the GENERAL SETTINGS
folder.
All information on this page is read only .
Pages 3-5: Analog Inputs & Compressor Information
Figure 60: Analog Inputs & Compressor Information
All information on these pages is read only .
The following analog inputs are displayed in this section:
Package Discharge Pressure
Sump Pressure
Airend Discharge Temperature
Injected Coolant Temperature
Aftercooler Discharge Temperature
Separator Pressure Drop
Coolant Filter Pressure Drop
Inlet Vacuum
Remote Pressure (optional)
Aftercooler Discharge Pressure (integrated dryer compressors only)
EN-
All manuals and user guides at all-guides.com
Figure 59: Counters
NOTICE
Icon
Meaning
Pressure
Temperature
NOTICE
Additionally, the following compressor status readings are included in this
section:
Motor Speed
Package kW
Average Package kW/hour
Average % Capacity
Average Capacity
Energy Cost
Energy Savings
Lifetime Energy Savings

Operator settings folder

Pages 1-2: Operator Settings
Figure 61: Operator Settings
The parameters below are adjustable at any time:
Table 22: Operator Settings
Operator
Default
Settings
Target Pressure
100
Automatic Stop
110
Target+1
Pressure
Immediate Stop
120
Pressure
% Savings
Modulation
Compared To
Energy Rate
0.000
Reset Averaging
--/--/--
EN
Min .
Max .
Step
Unit
65
145
1
psi
Target+10
1
psi
Auto
Auto+10
1
psi
---
---
---
---
0.000
9999.999
---
---
-
-
-
date
80446339 Rev C