9. INSTALL HOOD (
Remove the electrical compartment
cover. Insert the house wiring in the
hood and tighten the wire clamp to
secure the wiring.
Hold the hood until it is completely secured to the wood mounting strip.
Rest the back cavity of the hood on
the wood mounting strip.
Attach 10" round duct to adapter.
Secure the hood to wood mounting
strip with 4 screws no. 8 x 5/8'' (for 36''
width hood) or 6 screws (for 48'' and
60'' width hoods) provided at locations
shown. Drill two 3/16'' diameter holes
into the wall for wall anchors through
the existing holes in the inside hood
back in the locations shown. Then,
install both wall anchors with the
remaining no. 8 x 5/8'' screws and
both washers provided.
10. INSTALL DECORATIVE FLUE (OPTIONAL)
AEWPD Series
Refer to the instructions included with the optional decorative flue.
11. CONNECT WIRING
Risk of electric shock. Electrical wiring must be done by qualified personnel in
accordance with all applicable codes and standards. Before connecting wires,
switch power off at service panel and lock service disconnecting means to
prevent power to be switched on accidentally.
W
ATERPROOF WIRE CONNECTORS INSTRUCTIONS
1. Strip wires 3/8''.
2. Align frayed strands or conductors.
3. Do not pre-twist. Place stripped wires together with ends even, but lead smaller stranded wires
slightly ahead of larger solid or stranded wire.
4. Twist connector onto wires pushing firmly until hand-tight. DO NOT over torque.
5. When inserting wires into connectors, some sealant may leak out. Wipe off excess sealant in
and around conductors. DO NOT REUSE.
'
)
CONT
D
HD0464
CAUTION
HD0463
WARNING
!
:
E
LECTRICAL COMPARTMENT COVER
- 7 -