Owner's Manual – DrizAir Dehumidifier
DrizAir Dehumidifiers are commercial refrigerant dehumidifiers, designed for drying building structures
and contents. They are designed for high performance water removal, as well as durability and ease of use.
Safety Information
Keep Children Away: Do not allow children to play with or
around the unit, which could result in injury. Be sure the unit is
inaccessible to children when not attended.
Keep Unit Grounded: Always operate the unit with a grounding
plug and a grounded electrical outlet. A grounding plug is an
essential safety feature that helps reduce the risk of shock or
fire.
Protect Power Cord from Damage: Never operate a unit with a
damaged power cord, as this may lead to electrical or fire haz-
ards. If the power supply cord is damaged, it must be replaced
by a cord of the same type and amperage rating.
Extension Cords: Extension cords must be grounded and able
to deliver the appropriate voltage to the unit.
Handle With Care: Do not drop or throw the unit. Rough treat-
ment can damage the components or wiring and create a haz-
ardous condition.
Run on Stable Surface: Always operate the unit on a stable,
level surface, like the floor or a strong counter, so it cannot fall
and cause injury.
Secure During Transport: When transporting in a vehicle, se-
cure the unit to prevent sliding and possible injury to vehicle oc-
cupants.
Keep Out of Water: Never operate the unit in pooled or standing
water, as this may create a risk of injury from electrical shock. Do
not store or operate outdoors. If electrical wiring or components
become wet, thoroughly dry them before using the unit.
Keep Air Intakes Clear: Do not clog or block air intakes, as may
occur if operated to close to draperies or similar materials. This
may cause the unit to overheat and result in a fire or electrical
hazard.
Keep Filter Clean: Always use a clean air filter. Do not allow
any material to clog the filter, as this may cause the dehumidifier
to overheat. Do not allow oil, grease, or other contaminants to be
drawn into the dehumidifier.
Keep Electrical Components Dry: Never allow water inside the
dehumidifier's electrical components. If these areas become wet
for any reason, thoroughly dry them before using the dehu-
midifier.
Allow Repair Only by Qualified Person: Do not attempt to dis-
assemble or repair the unit if you are not qualified to do so. You
may handle some maintenance and troubleshooting, but make
sure that more complex problems are handled by an authorized
service technician. For information about authorized repair, call
Dri-Eaz at (360) 757-7776.
07-00265 G 12-02 Copyright 2000, 2002 Dri-Eaz Products, Inc.
DrizAir 80
DRI-EAZ PRODUCTS, INC.
15180 Josh Wilson Road, Burlington, WA USA 98233
Fax: (360) 757-7950 Phone: (360) 757-7776
Read And Save These Instructions
115-volt models
www.dri-eaz.com
HOW TO USE DEHUMIDIFIERS
DrizAir Dehumidifiers are designed to reduce water vapor or high
humidity in a building or part of a building. The purpose is to pre-
vent humidity damage, and to dry out wet materials such as car-
pet, carpet cushion, floors, walls, furniture, contents, lumber, and
structural materials.
To speed up the rate of evaporation, and dry out materials faster,
use Dri-Eaz TurboDryer airmovers. The DrizAir Dehumidifier will
be needed to remove the additional water evaporated by the
TurboDryers.
Positioning Dehumidifiers
The dehumidifier must be operated in an enclosed area to
achieve best efficiency. Close all openings to other areas of the
building, like windows and doors, to prevent moist air from mix-
ing with the air in the drying area. Keep traffic through doors at a
minimum. This forms a closed drying chamber.
Inside the drying chamber, air should circulate freely. Open inte-
rior doors and operate TurboDryer airmovers to maintain good
airflow to all areas.
Place the dehumidifier where there is no restriction to air flowing
through either the inlet or the outlet. Keep away from loose mate-
rials like curtains and drapes.
Under normal circumstances, place the dehumidifier in the cen-
ter of the room. To dry a specific area, place the dehumidifier so
the outlet air points at the wet area and the warm, dry air passes
across it. The duct should never be closer than three feet from
the wall.
The DrizAir Dehumidifier warms the air as it removes its mois-
ture. In smaller rooms this can raise the temperature substan-
tially. Room temperatures of about 68° to 80° F (20° to 27° C)
are usually a good condition for drying. Never allow the room
temperature to exceed 100° F (38° C), because this could dam-
age the dehumidifier or building contents.
OPERATING INSTRUCTIONS
1. Operate the DrizAir Dehumidifier only in the upright position.
If it has been in a horizontal position for any time over a few
minutes, let it sit in the upright position for at least 30 minutes
before starting. This allows oil to drain back into the com-
pressor, increasing its life.
2. Plug in to a standard outlet with the correct voltage and am-
perage for the unit. Push the ON switch. Listen for proper
operation of fan and compressor before leaving the unit unat-
tended.
3. Allow five minutes before restarting after the unit shuts off
for any reason. This will avoid damaging the compressor.
4. If your unit has a pump, run the pump drain hose into a sink,
toilet, drain, or bucket. Make sure the hose is not kinked. If

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Dri-Eaz DrizAir 80

  • Página 1 Dri-Eaz at (360) 757-7776. 4. If your unit has a pump, run the pump drain hose into a sink, toilet, drain, or bucket. Make sure the hose is not kinked. If 07-00265 G 12-02 Copyright 2000, 2002 Dri-Eaz Products, Inc.
  • Página 2: Electrical Connections

    Then push back up in the pump and leak out. The control panel may signal the PURGE switch. When using the DrizAir 80, tip the unit this problem by displaying “ER9.”...
  • Página 3: Troubleshooting

    Airflow through unit restricted Increase airflow; clean filter and coils Pump does not function Stuck float valve Clean float valve shaft FOR PARTS AND SERVICE CALL YOUR LOCAL DISTRIBUTOR, or the Dri-Eaz Service Department at (360) 757-7776 Copyright 2000, 2002 Dri-Eaz Products, Inc.
  • Página 4: Directives De Sécurité

    Pour accélérer le taux d’évaporation et sécher plus vite le L’unité ne doit jamais fonctionner avec un câble secteur endom- matériel, utilisez les circulateurs d’air séchoir Turbo Dri-Eaz. magé, pour éviter les risques d’incendie ou liés à l’électricité. Si Vous aurez besoin du déshumidificateur DrizAir pour enlever le câble secteur est endommagé, il doit être remplacé...
  • Página 5: Connections Electriques

    Puis appuyez sur le tion ou de toute autre origine. L’appareil pourrait sinon surchauf- bouton PURGE. Si vous utilisez le DrizAir 80, basculez-le en fer, ce qui entraînerait une panne du compresseur ou tout autre arrière à...
  • Página 6: Depannage

    La pompe ne fonctionne pas Soupape à flotteur bloquée Nettoyez l’arbre de la soupape à flotteur POUR DES PIECES ET REPARATIONS CONTACTEZ VOTRE DISTRIBUTEUR LOCAL, ou le Service de Réparation Dri-Eaz au (360) 757-7776 Copyright 2000, 2002 Dri-Eaz Products, Inc.
  • Página 7: Información De Seguridad

    Para acelerar la evaporación y secar los materiales más rápida- que esto podría ocasionar un riesgo de incendio. Si el cable de mente, utilice las turbosecadoras Dri-Eaz. El deshumidificador suministro eléctrico está dañado, deberá cambiarlo por un cable DrizAir será necesario para eliminar el resto del agua evaporada del mismo tipo y amperaje.
  • Página 8: Conexiones Eléctricas

    A continuación pulse el interruptor dando lugar a un fallo del compresor o a otros problemas. No PURGE. Si utiliza el modelo DrizAir 80, incline la unidad hacia ponga en funcionamiento la unidad si está llevando a cabo trabajos atrás hasta alcanzar un ángulo de unos 30 grados;...
  • Página 9: Resolución De Problemas

    Sustituya o repare el cable roto o suelto Relé defectuoso Compruebe el relé con un voltímetro o amperímetro El compresor no funciona Póngase en contacto con el distribuidor o con Dri-Eaz Pro- ducts La rueda del ventilador no gira Ventilador obstruido...

Tabla de contenido