EXTINGUISHING THE APPLIANCE
1. Press the stop button (8 in figure A) to move the wick down. If the wick does not lower entirely, turn the
wick positioning knob (7 in figure A) counterclockwise until it is as low as possible.
2. After two or three minutes, lift the burner by grasping the spring and checking that it is unlit.
To minimise the odour given off on extinguishing, you can hold the wick positioning button when you press
on off, then turn it slowly to the bottom point and thus cause a slight slowing of the wick combustion speed.
If you see that there is a blue flame at the wick, do not worry. It lasts approximately five minutes, the time
needed to burn off the residual gases in the upper part of the wick housing.
WARNING:
Your appliance may stop on its own. This means that the temperature in your room is sufficient and that
the mechanism has tripped out as a safety measure.
This occurs when the temperature in the room reaches approximately 25 , depending on the weather
conditions and the volume in the room.
CHECKING AND REGULARLY MAINTAINING YOUR
CAUTION: It is absolutely prohibited to work on the following components:
Maintain your heating appliance clean, wipe it regularly, check there are no signs of grease and clean
any fuel runs that may have been deposited on the tank during filling, to prevent the emanation of
unpleasant smells.
Check the condition of the fuel tank on each fill. If it is leaky, dented or shows signs of rusting, replace
the tank immediately. You can obtain a new one from your dealer or your after-sales service.
APPLIANCE
- Safety system
- Fuel gauge
19