Craftsman 919.153090 Manual Del Propietário página 19

Ocultar thumbs Ver también para 919.153090:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

All manuals and user guides at all-guides.com
PROBLEM
Compressor is not
Prolonged excessive use of air. Decrease amount of air
supplying enough
air to operate acces-
Compressor is not large
sories.
enough for air requirement.
Hole in hose.
Air leaks.
Motor will not run.
Fuse blown, circuit breaker
tripped.
Extension cord is wrong length
or gauge.
Loose electrical connections.
Faulty motor.
CAUSE
usage.
Check the accessory air
requirement. If it is higher
than the SCFM or pres-
sure supplied by your air
compressor, you need a
larger compressor.
Check and replace if
required.
Tighten any exposed
fittings.
Check fuse box for blown
fuse and replace as
necessary. Reset circuit
breaker. Do not use a
fuse or circuit breaker
with higher rating than
that specified for your
particular branch circuit.
Check for proper fuse.
You should use a time
delay fuse.
Check for low voltage
problem.
Check the extension
cord.
Disconnect the other
electrical appliances from
circuit or operate the
compressor on its own
branch circuit.
Check the extension
cord.
Check wiring connection
inside terminal box.
Have checked by
a Trained Service
Technician.
19 - ENG
CORRECTION

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido