U
Safety Notes
Gloves should be worn during installation to prevent
U
crushing and cutting injuries.
The hot and cold supplies must be of equal
U
pressures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The fitting must be installed, flushed and tested after
the valid norms.
• As a standard, the mixer is supplied with a C aerator.
If the water jet tends to splash when hitting the sink,
exchange the C aerator for the aerator (comprised in
the delivery) which has a lower flow rate.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
Hansgrohe mixers can be used together with
hydraulically and thermically controlled continuous flow
heaters if the flow pressure is at least 0,15 MPa.
The product is exclusively designed for drinking water!
4
All manuals and user guides at all-guides.com
English
max. 1 MPa
0,1 – 0,5 MPa
1,6 MPa
max. 80°C
65°C
≥70°C / max. 4 min
Assembly see page 31
Symbol description
Do not use silicone containing acetic acid!
Dimensions (see page 35)
Flow diagram
(see page 35)
C-aerator
aerator 8 l/min
Operation (see page 36)
Hansgrohe recommends not to use as
drinking water the first half liter of water
drawn in the morning or after a prolonged
period of non-use.
Cleaning (see page 38)
and enclosed brochure.
Spare parts (see page 37)
XXX= Colors
000
chrome plated
800
stainless steel optic
Test certificate (see page 40)