Model: MZ-VDP-NA262F
Exit Button
Unlock Time
(2S-10S)
SPK
(VOL)
Indoor
monitor
Red:VCC
White:AUDIO
Black:GND
Yellow:ViDEO
Status LED
indicator
SET
GB - 11
DOOR
EXIT
Pulse electric
lock
NO
COM
COM
NC
Magnetic lock
Operation mode for outdoor doorbell
Model: MZ-VDP-NA262F
1: Modify the administrator password
123456 + # + 0 + # + XXXXXX+ # + *
Administrator
new password
password
2: Add unlock password
123456 + # + 1 + # + XXX + # + XXXXXX + # + **
1: Mode to add
Administrator
Serial number
new password
password
Example:
serial number 012
password 222333
123456 + # + 1+ # +012 + # +222333 + # +**
3: Add RFID card unlock
123456 +
# +
3
+
# + XXX + # + RFID card
Administrator
3: Mode to
Serial number
password
add RFID card
4:Add fingerprint unlock
123456 + # + 5 + # + xxx +
Administrator
5: Mode to add
serial number
password
fingerprint
5:Delete password/RFID/fingerprint user
Delete by serial number
123456 + # + 2 / 4 / 6 + # + XXX + # + **
2: Delete password
Administrator
4: Delete RFID
password
6: Delete fingerprint
Clear users by category
123456 + # + 2 / 4 / 6 + # + 99 + # + *
2: Delete password
Administrator
4: Delete RFID
password
6: Delete fingerprint
Long press the setting button on the back of the device for 3S, then short press the
setting 3 times to restore to the factory mode
Backlight LED settings
123456 + # + 7 + # + 00 /01 /02 + # + *
new password
+ # + **
Swipe RFID card directly
# +
+ # + **
Please record every direction of your
fingers as much as possible, record at
least 2 fingers
serial number
99 is delete all
00: Closed in any state
01: It lights up in any state
02: Closed at standby mode,lights up at working
GB -12