Anomalies
ANOMALY
The equipment does not
switch on
The equipment does not cool
sufficiently
If the Service Centre must be contacted, always communicate:
- the date of purchase;
- the data of the equipment found on the rating plate (last pages of this manual);
- the fault detected.
REPAIRS AND SPARE PARTS
Do not try to repair the equipment as this could cause serious harm to people, animals and property and will render the
warranty null and void. Always request the intervention of an Authorised Service Centre and request ORIGINAL spare parts.
EN
CAUSE
A) The switch of the equipment or that of the
electrical panel is NOT in the ON position.
B) The circuit breaker of the electrical panel is
NOT armed.
C) The power supply is interrupted.
D) The power cable is damaged.
E) The fuse is damaged.
F) Condenser overload due to insufficient
cooling.
A) The set temperature is too high.
B) The equipment is exposed to direct sunlight
or direct sources of heat.
C) The seals of the doors/drawers are damaged
and they do not close perfectly.
D) The ventilation grids of the condenser are
dirty or obstructed by objects.
D) No refrigerant gas.
F) Faulty internal probe or thermostat.
SOLUTION
A) - B) Restore the correct conditions of use.
C) Wait for the correct conditions of use to be
restored.
D - E) Contact a Service Centre for replacement.
F) Disconnect the power supply and clean the
condenser fins with a vacuum cleaner.
A) Verify the temperature settings.
B) Move the equipment or protect it with
special devices.
C) Contact a service centre for replacement.
D) Disconnect the power supply and clean the
condenser fins and the ventilation openings
with a vacuum cleaner.
E - F) Contactact a service centre.
20