Clearing Errors
Errors are indicated in the display by an error code and
the display background turning red.
Error code
Cause
Too little or no ultraviolet reaction from the
A
bank note.
Too little or no magnetic reaction from the
b
bank note.
Bank notes detected as being chained.
C
Bank notes as half bank notes.
F
Bank note count sensor
E01
Coding disk sensor
E03
Infeed tray sensor
E04
Output tray sensor
E05
Maintenance
Cleaning the Sensors
Bank notes are often soiled, particularly by dust. The
dirt deposits on the sensors during the counting
process. Soiled sensors are the most frequent cause of
malfunctions.
Clean the sensors with the brush supplied. Open the
bank note counter to clean the sensors. How to open
the bank note counter is described in the following
steps.
18
A frequent source of errors is soiling of the sensors
(see Cleaning the Sensors).
Solution
Remove critical notes from the batch.
Check the sensitivity setting of the UV sensor.
Remove critical notes from the batch.
Check the sensitivity setting of the MG sensor.
Check whether the bank notes stick together
and count the batch again.
Remove critical notes from the batch and
check for signs of damage.
Clean the sensor for counting the notes or
replace with a new one.
Clean the sensor for the coding disk or replace
with a new one.
Clean the sensor for the infeed tray or replace
with a new one.
Clean the sensor for the output tray or replace
with a new one.
Æ Grip the bank note infeed at the sides and remove the
infeed vertically out of the machine. Do not grip the infeed
in the middle section.
G