Technical Data; Accuracy; Ambient Conditions; Power Supply - Balluff BTL6-V11V-M-A1-S115 Serie Manual De Instrucciones

Ocultar thumbs Ver también para BTL6-V11V-M-A1-S115 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

BTL6-V11V-M _ _ _ _ -A1-S115
Magnetostrictive Linear Position Sensor – Profile Style
7

Technical data

7.1

Accuracy

The values are typical at 24 V DC, room temperature and a
nominal length of 500 mm together with magnet
BTL6-A-3800-2 or BTL6-A-3801-2.
The BTL is fully operational immediately, with full accuracy
after warm-up.
For special versions, other technical data may
apply.
Special versions are indicated by the suffix -SA
on the part label.
Resolution
Repeat accuracy, typical
Sampling rate
nominal length ≤ 275 mm
nominal length ≤ 600 mm
Non-linearity at
nominal length ≤ 500 mm
nominal length > 500 mm
Temperature coefficient
1)
7.2

Ambient conditions

Ambient temperature
Storage temperature
Relative humidity
Shock rating
Continuous shock
per EN 60068-2-27
3)
Vibration
per EN 60068-2-6
3)
Degree of protection as per IEC
60529 with connector installed
12
english
< 15 μm
< 20 μm
250 μs...3.5 ms
≥ 0.5 ms
±200 µm
±0.04 % FS
≤ 20 ppm/K
2)
0 °C...+70 °C
−40 °C...+100 °C
< 90%,
non-condensing
50 g/6 ms
50 g/2 ms
12 g, 10...2000 Hz
IP67
7.3

Power supply

Stabilized voltage
4)
Ripple
Current draw (at 24 V DC)
Inrush current
Reverse polarity protection
Overvoltage protection
Dielectric strength
(GND to housing)
7.4

Output signals

Short circuit resistance
7.5

Dimensions, weights

Housing diameter
Nominal length
Weight (depends on length)
Housing material
1)
Nominal length = 500 mm, magnet in the middle of the measuring range
For
: Use in enclosed spaces and up to a height of 2000 m above sea
2)
level.
Individual specifications as per Balluff factory standard, resonant
3)
frequencies excluded
For
: The BTL must be externally connected via a limited-energy
4)
circuit as defined in UL 61010-1, a low-power source as defined in
UL 60950-1 or a class 2 power supply as defined in UL 1310 or UL 1585.
20...28 V DC
≤ 0.5 V
pp
≤ 75 mA
≤ 4 A
up to 36 V
up to 36 V (power lines
only)
500 V DC
Signal cable to GND
30 mm
50...4012 mm
Approx. 1 kg/m
Aluminum

Publicidad

Tabla de contenido
loading

Tabla de contenido