5. Installation
Use multi-core insulated copper wire of at least 6 mm² and strip
± 5 mm.
Do not short-circuit or reverse polarity of battery, solar panel or
load, as this will lead to irreversible damage.
6. Protection Modes
V. 02 – 19/02/2019
SOL30UC12V/SOL30UC24V
Mount the regulator in a cool and ventilated, but dry location
using the four mounting holes. Use M4x20 screws (not
included) for easy mounting.
First, connect a 12 V (SOL30UC12V) rechargeable battery
(not included) or a 24 V (SOL30UC24V) rechargeable
battery (not included) to connections. Use the correct
polarity!
Then connect a solar panel (not included) to connections.
Make sure the connected solar panel is in accordance with
the specifications of this regulator. Use the correct polarity!
Finally connect a DC device or appliance (not included) to
connections. Make sure the connected load is in accordance
with the specifications of this regulator and switched off. Use
the correct polarity!
When connecting an AC load (not included), install a suitable
DC-to-AC convertor (not included) between battery and
load.
To disconnect the regulator, first disconnect the solar panel,
then the load and finally the battery.
Note that shorter connection wires will reduce power losses.
Over-discharge protection mode. This mode will be
enabled when the battery voltage becomes too low. The
power to the output connectors is cut off to prevent damage
to the battery. Remove the load from the connector and wait
until the battery is fully recharged.
Over-charge protection mode. This mode will be enabled
when the battery voltage becomes too high. The power from
the solar panel input connector is cut off to prevent damage
to the battery until the voltage drops below an acceptable
level.
5
©Velleman nv