7. Use
The LCD can show either battery voltage (A), discharge (output)
current from battery to load (B) or charging current from solar
panel to battery (C). Use the switch to scroll through the display
modes, refer to the icons on top to know what is being displayed.
V. 02 – 19/02/2019
SOL30UC12V/SOL30UC24V
Over-load protection mode. This mode will be enabled
when the load draws a current of more than 30 A.
Load short circuit protection mode. Enabled when a short
circuit in the load is detected.
Reverse polarity protection: in order to prevent possible
damage the regulator will not function when reversed
connecting polarity is detected. Correct the polarity to use
the regulator.
Battery voltage. Load on/off switch has
no function.
Output current from battery to DC-load.
Indicates 0.00 A when load is switched
off.
Use the load on/off switch to switch the
output current to the load on or off.
Note: In over-discharge protection mode
trying to switch on output to the load will
fail and a buzzer will sound. When the
system recovered from over-discharge
protection mode (battery charge level
back to normal) press the load on/off
switch two times to restart output current
to the load.
Charging current from solar panel to
battery. Load on/off switch has no
function.