SFA SANIMARIN 31 Instrucciones De Instalación página 13

Ocultar thumbs Ver también para SANIMARIN 31:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 20
1 0
SERVICE
• Normal non-foaming household bleaches/WC cleansers can
be used with this unit.
1 1
WINTERING
• In the event of a long period without use, rinse the bowl and
carry out several flushing cycles with a supply of fresh water.
1 2
FAULT FINDING
In most cases, any inconsistencies in the operation of the unit will
be minor and easy rectified. Please refer to the chart below. If the
problem cannot be easily remedied thanks to this chart, please call
our SFA Service organisation or go to a SFA-approved technician.
Disconnect the electrical power supply, before
attempting any work on the unit.
SYMPTOM
PROBABLE CAUSES
• The cycle proceeds
• The evacuation is clogged
correctly, the motor
turns but water in the
bowl empties slowly or
not at all
• The height of evacuation is
• The cycle proceeds
correctly, but some
too great
water remains in the
• The discharge pipe is pinched
bowl after a cycle
• The motor rattles or
• Foreign body into the bowl.
crunches
• After the button on
• Faulty programmer
the control console has
• Faulty control console
been pressed, the cycle
does not start
• The cycle engages but
• The inlet filter of the solenoid
little water runs in
valve (18) is clogged.
the bowl
• The water feed pipe is
pinched.
• The cycle engages but
• The stop valve is closed.
water does not run in
• The solenoid valve (18) is
the bowl
defective.
1 3
GUARANTEE
2 years guarantee from date of purchase, subject to correct
installation and correct use: disposal of toilet papers and fecal
matter only. Guarantee is limited to replacement or service
of the defective spare parts, and any indemnity or claim for
damages will not be included.
Freight and packing costs, travel expenses are not included in
the guarantee. It does not cover any normal deterioration of
the material over time, any external deterioration or accident,
incorrect disposal of sanitary products. Any modification wit-
hout prior notice will not be under guarantee. Fixing,
modification, or replacement of parts without our agreement
will not be guaranted, and will invalidate it. Our liability is
solely for the product itself.
Guarantee starts from date of purchase we may request a
copy of the invoice to validate the purchase date.
REMEDIES
• Dismount and clean the discharge pipe.
• Modify the installation.
• Check the route of the discharge pipe.
• Disconnect the motor supplies.
• Close water admission.
• Remove the motor unit.
• With a hook, withdraw all the matters being
able to obstruct the rotation of macerator.
• With a tool, turn the turbine in the
2 directions until rotation is free.
• Re-connect the motor supplies and press on
the pneumatic contactor to control the
correct operation of unit.
• Open water supply.
If the macerator remains blocked, we
recommend to call the SFA service.
• Replace the control console
• Call an SFA service agent.
• Clean the filter of the solenoid valve.
• Check the water admission pipe.
• Open the stop valve.
• Change the solenoid valve.