Internal Battery Replacement - Tripp-Lite SmartOnline Manual Del Propietário

Ocultar thumbs Ver también para SmartOnline:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Internal Battery Replacement

Battery Replacement Door: Under normal conditions, the original battery in your UPS will last several years. Battery replacement
should be performed only by qualified service personnel. Refer to "Battery Warnings" in the Safety section. If you require a replacement
battery, you can find it at www.tripplite.com/support/battery/index.cfm. See the chart below to find the right replacement battery for your
UPS system:
UPS Model
SU750RTXLCD2U
SU1000RTXLCD2U
SU1500RTXLCD2U
SU2200RTXLCD2U
SU3000RTXLCD3U
See the following diagrams for battery removal and installation procedures.
2U Models
Note: The SU1500RTXLCD2U is shown, but the procedure is the same for all other 2U units.
1
Remove the 4 front screws from the front panel and remove.
Unplug the LCD connectors to remove it completely.
2
Flip open the white connector holder. Disconnect the connector
that's inside the white connector holder.
3
Remove the two screws that hold the metal bar in place
(behind the front panel on the right side). Slide the metal bar
to the left and remove it from the UPS.
13-11-176-93-3156.indb 26
Replacement Battery Cartridge
RBC24V-LCD
RBC24V-LCD
RBC94-2U
RBC94-2U
RBC96-3U
1
2
3
26
11/27/2013 4:25:04 PM