OPERATION
Controls (Fig.1)
A
B
C
D
R
Button A = Lights on/off.
Button B = Activates/Deactivates the delay-off feature. Press once (when blower is on)
to activate the delay-off feature. The selected speed level that is displayed in display "C"
will blink when this feature is activated. After 10 minutes, the blower will then turn off.
Delay can be deactivated at any time by pressing the button again.
Display C = Indicates the selected speed of the blower 1, 2, 3, or b for boost.
"-" indicates the need to clean the grease filter or replace the non-duct filter.
Button D = Turns on the blower. Hood will turn on to the last speed selected. The blower
speed will change each time the button is pushed (from 1 to "b"). To turn the blower off,
press and hold button for approximately 2 seconds.
Button R = Filter clean indicator reset. Press and hold for 2 seconds to reset the indicator.
Note: The "-" must be displayed when pressing the reset button.
Auto Shut-Off Feature
If the blower and/or the lights are on continuously for 10 hours without any user
interaction with the controls, the hood will automatically shut off. Press any control button
to re-activate the hood.
HEAT SENTRY™
Your hood is equipped with a HEAT SENTRY™ thermostat. This thermostat is a device
that will turn on or speed up the blower if it senses excessive heat above the cooking
surface.
1) If blower is OFF - it turns blower ON to HIGH speed.
2) If blower is ON at a lower speed setting - it turns blower up to HIGH speed.
When the temperature level drops to normal, the blower will return to its original setting.
WARNING
The HEAT SENTRY thermostat can start the blower even if the hood is turned OFF.
When this occurs, it is impossible to turn the blower OFF with its switch. If you must
stop the blower, do it from the main electrical panel.