Troubleshooting

Problem
Cause
The motor does not
• There is no power.
start.
• Stuck impeller.
The motor is turning
• Clogged foot valve filter.
but it is not pumping
• Excessive suction height.
water.
• Air in the admission.
Insufficient flow speed.
• Suction height in the limit.
• Foot valve filter partially clogged.
The motor thermal
• The motor is overheated.
protection was
• The impeller is stuck.
activated.
Solution
• Check the connection and voltage values.
• Release it with a screwdriver (see page 8).
• Clean the filter.
• Reduce the length of the suction pipe.
• Check the suction pipe is hermetic. Double check the foot
valve is submerged at least 1.5 ft.
Purge the pump once more (see page 7)
Check the suction height.
• Shorten the suction pipe length.
• Clean the foot valve and the whole suction pipe if necessary.
• Check voltage and ventilation.
• Release it with a screwdriver (see page 8).