Setting The Dmx Start Address; Temperature Indication And Overheat Control; Cleaning The Spotlight; Dmx Channels And Functions - IMG STAGELINE PARC-64/CTW Manual De Instrucciones

Ocultar thumbs Ver también para PARC-64/CTW:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 20
IMG STAGELINE) . For cable lengths exceeding 150 m,
it is generally recommended to insert a DMX level
matching amplifier (e . g . SR-103DMX) .
1) Connect the DMX INPUT (4) to the DMX output
of the light controller or to the DMX output of
another DMX-controlled unit .
2) Connect the DMX OUTPUT (6) to the DMX input
of the following DMX unit . Connect the output of
this DMX unit to the input of the following DMX
unit etc . until all DMX-controlled units have been
connected in a chain .
3) To prevent interference in signal transmission, in
case of long cables or a multitude of units con-
nected in series, terminate the DMX output of the
last DMX unit in the chain with a 120 Ω resistor
(> 0 .3 W): Connect a corresponding terminating
plug (e . g . DLT-123) to the DMX output jack .

5.3.2 Setting the DMX start address

For separate control of all DMX units connected to
the light controller, each unit must have its own start
address . Example: If the first DMX channel of the
spotlight is to be controlled by the controller via DMX
address 17, set the start address on the spotlight to
17 . All other DMX channels of the spotlight will be
automatically assigned to the following addresses
(i . e . 18 – 20 in case of start address 17) .
1) Press the button MENU repeatedly until
pears on the display .
2) Press the button ENTER . The start address adjusted
(
...
3) To set the desired address, press the buttons UP
and DOWN . Now the spotlight can be operated
with the light controller .
Notes:
1 . If the DMX control does not work, call up the menu
item
and press the button ENTER .
pear on the display . If
use the button UP or DOWN to switch to
2 . When the menu item
pears on the display and DMX signals are available
at the DMX input (4), the dot at the right end of the
display will flash .

5.3.3 DMX channels and functions

DMX
DMX value
channel
1
000 – 255
2
000 – 255
3
000 – 255
000 – 010
4
011 – 255
DMX channels
10
) will be indicated .
appears on the display,
,
,
or
Function
dimmmer 0 %  100 %
basic brightness cool white
basic brightness warm white
stroboscope off
stroboscope slow  fast
5.4 Temperature indication and
overheat control
The spotlight is equipped with an overheat control .
When the temperature inside the spotlight is too
high, the spotlight will be switched off . After cool-
ing down, the spotlight will be switched on again
automatically . To indicate the inside temperature:
1) Press the button MENU repeatedly until
appears on the display .
2) Press the button ENTER .
display .
3) Press the button ENTER again . The inside temper-
ature (in °C) is indicated on the display .
4) To exit the menu branch, press the button MENU .

6 Cleaning the Spotlight

Clean the plastic filter in front of the LEDs at regular
intervals or as required . This is the only way to ensure
that light will be radiated at maximum brightness .
Before cleaning, disconnect the mains plug from
the socket. Only use a dry, soft cloth and a mild
detergent . Then carefully wipe the plastic filter dry .
For cleaning the other parts of the housing, only
use a dry, clean cloth . Never use any fluid; it may leak
into the spotlight and damage it .
ap-
7 Specifications
Data protocol: . . . . . . . . . . DMX 512
Number of DMX channels: 4
Light source: . . . . . . . . . . . white COB LED
Power consumption: . . . 100 W
Beam angle: . . . . . . . . . 60°
Colour temperature: . . . adjustable
must ap-
Power supply: . . . . . . . . . . 230 V/ 50 Hz
.
Power consumption: . . . . . 110 VA max .
ap-
Dimensions: . . . . . . . . . . . ∅ 220 mm × 260 mm
Weight: . . . . . . . . . . . . . . 2 .9 kg
Subject to technical modification .
All rights reserved by MONACOR
Co. KG. No part of this instruction manual may be reproduced
in any form or by any means for any commercial use.
will appear on the
2700 K – 5600 K
INTERNATIONAL GmbH &
®

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

38.6920

Tabla de contenido