EN
- Absolutely never put the following into the compressed air circuit: hydraulic or Vaseline oil, brake liquid,
kerosene or other liquids.
-Install a filter dehumidifier-lubricator unit in the compressed air system.
- If you want to lubricate the compressed air circuit use exclusively:
ACCESSORIES
The jack is supplied with two extensions or height adapters (120 mm the long extension, 70 mm the short
extension), a circular tooth plate (10 mm plate) and an extension holder.
THE MANUFACTURER IS NOT LIABLE FOR ANY DAMAGE RESULTING AS A CONSEQUENCE
OF DISREGARD FOR THE ABOVE INDICATIONS AND THE WARRANTY CONDITIONS ARE
SCRAPPING AND DISPOSAL
- The lubricants must be disposed of in compliance with the anti-pollution laws in force.
- Scrapping the jack and its component parts must be carried out by the user in accordance with current laws.
USE
- Expressly observe the safety rules already described in this manual.
1) Position the jack under the supports as described in the manual of the vehicle
the manufacturing company is not responsible for any break or damage to the lifted vehicle or to
persons or property due to an incorrect use of the jack.
2. The handle positioning lever (A) is on the left in relation to the worker; by moving it upwards the
stopping system is released so the worker can then choose one of the three possible handle posi-
tions. DWG. 13
3. When control (B) is in the perfectly central position, the jack is in the idle status.
4. By turning control B, located near the handle, towards the right in relation to the worker, the jack lifts the load.
5. By turning control B, located near the handle, towards the left in relation to the worker, the jack lowers the
load. DWG. 13
6. After lifting the load, it is absolutely essential to rest it on the support stands before doing any work under it.
REMEMBER THAT THE JACK IS A LIFTING DEVICE AND NOT A SUPPORTING DEVICE!!!
- The operator's employer will have to provide the necessary training and furnish the necessary
information about the pumping and shifting forces.
- If the distributor breaks during use, work directly on the flow of air, closing the safety cock no. 398, between
the quick coupling of the air inlet and the distributor itself. DWG. 14
- Before working with the jack, it is advisable to perform a few operations with no load in order to
acquire the sensitivity necessary to work safely with the jack.
15
AGIP OSO 100; MOBIL DTE 27; ESSO TERESSO 100;
SHELL TELLUS 100; BP ENERGOL HP 100
NEVER USE MORE THAN TWO EXTENSIONS!
INVALIDATED THEREOF!