WIKA TGS55 Manual De Instrucciones página 18

Termómetros con contacto inductivo 831, para zonas potencialmente explosivas
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

5. Commissioning, operation
When screwing the instrument in, the force required to do this must not
be applied through the case, but only through the spanner flats provided
for this purpose, and using a suitable tool.
EN
Installation with
open-ended spanner
When mounting a thermometer with adjustable stem and dial, the
specific instructions must be followed. The following steps must be taken
in order to set the indicator to the desired position:
1. Loosen the lock nut or union nut at the process connection.
2. Loosen the hexagon bolts and slotted screws at the swivel joint.
3. Position the indicator as required, tighten the hexagon bolts and
slotted screws, and finally tighten the lock nut or union nut firmly.
18
WIKA operating instructions models TGS55, TGS73 with 831 (Ex)
loosen
Make sure to loosen the
screws on the opposite side
as well!

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Tgs73

Tabla de contenido