Front Panel - Wagan Tech Slimline 800 Manual De Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Slimline
Power Inverters by Wagan Tech

FRONT PANEL

All inverters described in this manual have an ON/OFF rocker switch, two LED
indicators, and multiple AC outlets. Actual locations of these components vary by
model. Multiple AC outlets enable multiple appliances to be operated at one time.
ON/OFF Switch – Controls operation of the inverter. The below indicators operate
when the switch is ON.
Green LED – When lit, indicates the inverter is on and operating normally. AC is
present at the outlets.
Red LED – When lit, indicates the inverter has shut down for any of the following
reasons:
1. Low DC battery voltage – less than 10.5V
Preceded by an audible alarm. Charge the battery as soon as possible.
2. High battery voltage – greater than 15V
3. Over temperature − Shut off the inverter and let it cool before restarting.
4. Overload – reduce the AC appliance load.
Audible Alarm (not shown)
getting low and the inverter is about to shut down. If you can reduce the AC load,
you can temporarily extend operating time. Charge the battery as soon as possible.
3
when it sounds, it indicates that the battery voltage is
www.wagan.com
®
Vents
Power On Indicator (green)
Fault Indicator (red)
ON/OFF Switch
2x AC Outlets