To reduce the risk of fire and burn
injury, use only spark plugs
authorized by STIHL. Always press
spark plug boot (2) snugly onto
spark plug terminal (1) of the proper
size. (Note: If terminal has
detachable SAE adapter nut, it must
be attached.)
A loose connection between spark
plug boot and ignition wire
connector in the boot may create
arcing that could ignite combustible
fumes and cause a fire.
MS 210, MS 210 C, MS 230, MS 230 C, MS 250, MS 250 C
Replacing Starter Rope
and Rewind Spring
:
Remove the screws (1).
:
Push the hand guard upward.
1
:
Pull the underside of the fan
housing away from the crankcase
and remove it downward.
1
1
1
1
English / USA
Versions with Easy2Start
5
6
:
Use circlip pliers to carefully remove
circlip (2).
:
Remove the washer (3), driver (4),
spring housing (5) and washer (6).
If no suitable circlip pliers are available,
have the starter rope or rewind spring
replaced by your STIHL dealer.
1)
Special version
1)
4
3
2