14. Accessories
No. 1821-0101 Stand for benchtop units,
WxHxD: 230 x 680 x 290 mm
[9.062 x 26.772 x 11.426 inches]
No. 1821-0200 Premix spatula
No. 1820-6500 Bowl, incl. paddle, 65 ml
No. 1820-6510 Paddle, 65 ml
No. 1820-6520 Bowl, 65 ml
No. 1820-0200 Bowl, incl. paddle, 200 ml
No. 1820-0210 Paddle, 200 ml
No. 1820-0220 Bowl, 200 ml
No. 1820-0500 Bowl, incl. paddle, 500 ml
No. 1820-0510 Paddle, 500 ml
No. 1820-0520 Bowl, 500 ml
No. 1820-0700 Bowl, incl. paddle, 700 ml
No. 1820-0710 Paddle, 700 ml
No. 1820-0720 Bowl, 700 ml
No. 1820-1001 Bowl, incl. paddle, 1000 ml
No. 1820-1010 Paddle, 1000 ml
No. 1820-1020 Bowl, 1000 ml
16. Error List
Error
ON/OFF switch fails to
work.
Motor fails to start.
No or insufficient vacu-
um build-up.
("Err" shown on the dis-
play + audible signal)
Vacuum reduction/ven-
ting too slow.
Vacuum pump conti-
nuously on.
Paddle fails to turn.
Possible cause
• Unit not connected to the power
outlet.
• Unit fuse blown.
• Faulty/damaged power cord.
• Motor fuse blown.
• Motor defective/damaged.
• Inlet filter blocked.
• Seal surfaces dirty.
• Vacuum pump defective/dam-
aged.
• Vent valve defective/damaged.
• Inlet filter blocked.
• Bowl detection pin jamming.
• Motor fuse blown due to paddle
overload.
15. Disposal instructions
for countries in the EU
To conserve and protect the environment, prevent
environmental pollution and improve the recycling of
raw materials, the European Commission adopted
a directive that requires the manufacturer to accept
the return of electrical and electronic units for proper
disposal or recycling.
Within the European Union units with this symbol
should not therefore be disposed of in unsorted do-
mestic waste:
For more information regarding proper disposal ple-
ase apply at your local authorities.
corrective action
• Check the power supply.
• Replace the fuse (refer to Sec. 8.3).
• Have the unit repaired.
• Replace the fuse (refer to Sec. 8.3).
• Have the unit repaired.
• Clean the filter (refer to Sec. 8.1).
• Clean the seal surfaces (refer to Sec. 8.2).
• Have the unit repaired.
• Have the unit repaired.
• Clean the filter (refer to Sec. 8.1).
• Have the unit repaired..
• Clean the paddle and bowl.
• Replace the fuse (refer to Sec. 8.3).