Classification in compliance with standard
EN 60335-2-69 – Annexe AA
Vacuum cleaners for dust harmful to health are classified
according to the following dust classification:
■
L (low risk) suitable for separating dust with an exposure
limit value of over 1 mg/m
occupied;
■
M (medium risk) for separating dust with an exposure
limit value of over 0.1 mg/m
occupied;
■
H (high risk) for separating all dust with an exposure limit
value lower than 0.1 mg/m
occupied, including carcinogenic and pathogenic dusts.
Dust emissions into the environment
Indicative values of performance:
■
version for dust harmful to health (Classes L, M, H):
L: retains at least 99.1% of particles measuring ≥ 3
μm;
M: retains at least 99,9% of particles measuring ≥ 3
μm;
H: class H13 HEPA filter in accordance with EN1822.
11/2008
, depending on the volume
3
, depending on the volume
3
, depending on the volume
3
General recommendations
WARNING!
Risk of fire outbreaks and explosions.
■
The vacuum cleaner can only be used when it
is certain that active sources of ignition are not
going to be vacuumed.
■
It is forbidden to vacuum the following materials:
▪ burning materials (embers, hot ashes, lighted
cigarettes, etc.);
▪ flammable liquids, aggressive fuels (e.g.
gasoline, solvents, acids, alkaline solutions,
etc.);
▪ explosive dust or ones liable to ignite in a
spontaneous way (such as magnesium or
aluminium dusts, etc.).
■
The vacuum cleaner is not suitable for vacuuming
explosive or similar substances, as established
by the laws governing explosive substances,
particularly: liquid fuels and mixtures of
flammable dust and liquids.
WARNING!
Emergency
If an emergency situation occurs:
■
filter breakage
■
fire outbreak
■
short-circuit
■
motor block
■
electric shock
■
etc.
Turn off the vacuum cleaner, unplug it and ask for
assistance from qualified personnel.
Check the place of work and substances tolerated for the
vacuum cleaner in ATEX variant.
WARNING!
The vacuum cleaners must not be used or stored
outdoors, or in damp places.
The vacuum cleaner is not suitable for vacuuming
liquids, it can only be used to vacuum dry materials.
3
ATTIX 170 / ATTIX 170 E
[ NOTE ]
I
GB
F
D
E
C328