Operating Precautions; Safety­PRecations - MrHeater MHI170QFAVT Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

OPERATING PRECAUTIONS

This­is­a­propane,­direct-fired,­forced­air­heater.­It's­intended­
use­is­primarily­temporary­heating­of­buildings­under­
construction,­alteration­or­repair.
Propane­is­heavier­than­air.­If­propane­leaks­from­a­
connection­or­fitting,­it­sinks­to­the­floor,­collecting­there­
with­the­surrounding­air,­forming­a­potentially­explosive­
mixture.­Obviously,­propane­leaks­should­be­avoided,­so­set­
up­the­propane­supply­with­utmost­care.­Read­enclosed­Odor­
Fade­and­Propane­Sheet­for­additional­information­about­
detecting­propane­leaks.­Leak­check­new­connections­or­
reconnections­with­a­soap­and­water­solution­and­follow­all­
connection­instructions­herein.­Also,­ask­your­propane­dealer­
for­advice­on­the­propane­application­and­supply­installation­
and­ask­him­to­check­it­if­there­are­any­questions.
This­heater­was­designed­and­certified­for­use­as­a­
construction­heater­in­accordance­with­ANSI­Standard­Z83.7/
CGA­2.14.­Check­with­your­local­fire­safety­authority­if­you­
have­any­questions­about­your­applications.­Other­standards­
govern­the­use­of­fuel­gases­and­heat­producing­products­
in­specific­applications.­Your­local­authority­can­advise­you­
about­these.
Direct-Fired­means­that­all­of­the­combustion­products­enter­
the­heated­space.­Even­though­this­heater­operates­very­close­
to­100­percent­combustion­efficiency,­it­still­produces­small­
amounts­of­carbon­monoxide.­Carbon­monoxide­(called­CO)­
is­toxic.­We­can­tolerate­small­amounts­but­not­a­lot.­CO­can­
build­up­in­a­heated­space­and­failure­to­provide­adequate­
ventilation­could­result­in­death.­
The symptoms of inadequate ventilation are:
­
•­headache­
­
•­dizziness
­
•­burning­eyes­and­nose­
­
•­nausea
­
•­dry­mouth­or­sore­throat
So,­be­sure­to­follow­advice­about­ventilation­in­these­
operating­instructions.
Forced­Air­means­that­a­blower­or­fan­pushes­the­air­through­
the­heater.­Proper­combustion­depends­upon­this­air­flow;­
therefore,­the­heater­must­not­be­revised,­modified­or­
operated­with­parts­removed­or­missing.­Likewise,­safety­
systems­must­not­be­circumvented­or­modified­in­order­to­
operate­the­heater.
When the heater is to be operated in the presence
of other people the user is responsible for properly
acquainting those present with the safety precautions
and instructions, and of the hazards involved.
Figure 1
VENTILATION:­Minimum­openings­required
­
Heater­
Forced­air­(MHI170QFAVT)­
Force-Air Propane Construction Heater
Opening­
Opening
near­floor­
near­ceiling
3­ft
­
3­ft
2
2
SAFETY PRECAUTIONS
1.­
Check­the­heater­thoroughly­for­damage.­DO­NOT­operate­a­
damaged­heater.
2.­ DO­NOT­modify­the­heater­or­operate­a­heater­which­has­been­
modified­from­its­original­condition.
3.­ Use­only­propane­gas.
4.­ Use­only­VAPOR­WITHDRAWAL­propane­supply.­If­there­is­any­
question­about­vapor­withdrawal,­ask­your­propane­dealer.
5.­ Mount­the­propane­cylinders­vertically­(shutoff­valve­up).­
Secure­them­from­falling­or­being­knocked­over­and­protect­
them­from­damage.
6.­ Locate­propane­containers­at­least­(USA)­7­ft.­(2.13m),­
(Canada)­10­ft.­(3m)­from­the­heater­and­do not­direct­exhaust­
toward­containers.
7.­
IMPORTANT­Use­only­the­hose­and­regulator­assembly­
provided­with­the­heater.­Match­the­color­stripe­on­the­hang­
tag­attached­to­the­hose­assembly­with­the­color­on­the­label­
located­near­the­propane­inlet­fitting­on­the­heater.­Inspect­
hose­assembly­before­each­use­of­the­heater.­If­there­is­
excessive­abrasion­or­wear,­or­hose­is­cut,­replace­with­hose­
assembly­listed­on­parts­list­before­using­heater.
8.­­ For­indoor­use­only.­Area­must­be­well­ventilated.­Figure 1.­
(also­see­"Operating­Precautions").
9.­ If­at­any­time­gas­odor­is­detected,­IMMEDIATELY­
DISCONTINUE­operation­until­the­source­of­gas­has­been­
located­and­corrected.­Read­enclosed­Odor­fade­and­Propane­
Sheet­for­additional­information­about­detecting­propane­leaks.
10.­ Install­the­heater­such­that­it­is­not­directly­exposed­to­water­
spray,­rain­and/or­dripping­water.
11.­ Maintain­minimum­clearance­from­normal­combustible­material­
(like­paper).­Figure 2.­
12.­ Due­to­the­high­surface­and­exhaust­temperatures,­adults­and­
children­must­observe­clearances­to­avoid­burns­or­clothing­
ignition.
13.­ Operate­only­on­a­stable,­level­surface.
14.­ Do­not­use­with­duct­work.­Do­not­restrict­inlet­or­exit.
15.­ Use­only­the­electrical­power­specified.­The­electrical­
connection­and­grounding­must­comply­with­National­Electrical­
Code­-­ANSI/NFPA­70­(USA)­and­CSA­C22.1­Canadian­Electrical­
Code,­Part­1­(Canada).
16.­ Use­only­a­properly­grounded­3-prong­receptacle­or­extension­
cord.
17.­ Do­not­move,­handle­or­service­while­hot­or­burning.
18.­ Do­not­adjust­the­heater­combustion­tube­elevation­while­
heater­is­running­or­hot.­Adjustments­to­elevation­should­only­
be­made­after­the­heater­has­cooled­to­touch.
19.­ Use­only­in­accordance­with­local­codes­or,­in­the­absence­of­
local­codes,­with­the­Standard­for­the­Storage­and­Handling­
of­Liquefied­Petroleum­Gases­ANSI/NFPA­58­and­CSA­B149.1,­
Natural­Gas­and­Propane­Installation­Code.
Figure 2: MINIMUM­CLEARANCE:­From­normal­combustible­materials
Clearance­
From­floor­ . ......................................................0­ft
From­outlet­ . ....................................................6­ft
From­sides­......................................................2­ft
From­top­ . ........................................................3­ft
Locate­10­ft.­from­canvas­or­plastic­tarpaulins­or­similar­
coverings­and­secure­them­to­prevent­flapping­or­movement­
due­to­wind­action.
3
Operating Instructions and Owner's Manual
­
Forced­Air­170QFAVT

Publicidad

Tabla de contenido
loading

Tabla de contenido