Front Panel 3000Ts; Pulling Set Controls Description - Oerlikon CITOLINE 3000T Instrucciones De Seguridad, Empleo Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 17
EN
In position
the welder operates in timed mode; press the
torch button to start the welding phase, which stops automatically
after the time interval as set on the timer potentiometer.
2 - Machine ON indicator lamp
3 - Machine overheating indicator lamp
4 - Wire feed speed control -potentiometer
5 - Spot welding time control potentiometer, from 0.3 to 10 sec-
onds (operating only with selector (Ref. 1 - Picture 1 Page 4.) set
to position
6 - Wire feed motor acceleration time control potentiometer.
7 - Control potentiometer to regulate time during which welding
power is maintained after the relative shutdown signal. In practice,
at the end of welding, if this time is too short, the wire remains
stuck in the bath or protrudes too far from the torch contact tube;
otherwise, if the control time is too long, the wire remains stuck in
the torch contact tube, often causing damage to the latter.
8 - Euro torch connector
9 - Quick connectors for ground clamp
10 - Power switch.
11 - Welding voltage adjustment switch.
INTERNAL PANEL CONTROLS
- Auxiliary circuit safety fuses
- Wire feed gearmotor
3.2

FRONT PANEL 3000TS

Picture 2.
13
11
16
11 - Welding tension regulation commutator
12 - Earth cable socket
13 - Control transformer protection fuse
14 - Pulling set protection fuse
15 - Warning light
16 - Power button and regulator commutator

PULLING SET CONTROLS DESCRIPTION

14
15
12
5 EN
4.0
PULLING SET CONTROLS DESCRIPTION
Picture 3.
1
5
6
7
8
1 - Welding system selector:
In position
press the torch button to start welding, and re-
lease to stop.
In position
press the torch button to deliver gas; on re-
lease, wire feed and current are activated; press again to stop wire
feed and current and release to shut off the gas supply.
In position
the welder operates in timed mode; press the
torch button to start the welding phase, which stops automatically
after the time interval as set on the timer potentiometer.
2 - Machine ON indicator lamp
3 - Machine overheated or anomaly warning light.
4 - Wire feed speed control -potentiometer
5 - Spot welding time control potentiometer, from 0.3 to 10 sec-
onds. Operating only with selector (Ref. 1 - Picture 3 Page 5.) set
to position
6 - Wire feed motor acceleration time control potentiometer.
7 - Control potentiometer to regulate time during which welding
power is maintained after the relative shutdown signal. In practice,
at the end of welding, if this time is too short, the wire remains
stuck in the bath or protrudes too far from the torch contact tube;
otherwise, if the control time is too long, the wire remains stuck in
the torch contact tube, often causing damage to the latter.
8 - Advance wire button (without "current")
9 - Gas output test button
10 - Euro torch connector
2
3
4
9
10

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Citoline 3000ts

Tabla de contenido