NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
11. WIRING DIAGRAM
BLOWER FAN
RPM SENSOR
OPERATING
PHOTO CELL
VIBRATION
12. SPECIFICATION
BLK
CN1 BHI
BHI
RED
YEL
BLUE
DISPLAY PCB
CN12
WHITE
(Dis 3P)
POWER LAMP
(LED)
CN8
SWITCH
BLACK
CN5
WHITE
CN9
WHITE
SWITCH
Figure 12. Wiring Diagram
647
MODEL
Heat Output-BTU/Hr.
Fuel Consumption-Gal/Hr.
Fuel Tank Capacity-Gal
Electronic Pump Pressure-PSI
Volts/Hz/Amps
Phase
Product Size(L×W×H, mm)
Packing Size(L×W×H, mm)
Net Weight(Kg)
Gross Weight(Kg)
LIMIT CONTROL
(OVERHEAT THERMOSTAT)
CN7
RED
C
CN4
WHITE
O
N P
CN13
BLACK
T C
R B
CN3
YELLOW
O
L
CN10
BLUE
CN1
(AC1)
CN2
FUSE
(AC2)
T4A/250Vac
SF70DGD
120/60/1.5
647 × 334 × 576
580 × 385 × 605
12
ELECTRONIC
E/P
PUMP
IGNITOR
SPARK PLUG
I.G
BLOWER
B/M
MOTOR
COOLING
C/M
MOTOR
BLACK
POWER
120Vac/60Hz
WHITE
CASE
EARTH
334
/SF70H
70,000
0.53
4
108
1
15.7
18.0