5. Specifications
BlueSolar Charge
Controller
Battery voltage
Rated charge current
Nominal PV power, 12V 1a,b)
Nominal PV power, 24V 1a,b)
Maximum PV open circuit
voltage
Max. PV short circuit current 2)
Maximum efficiency
Self-consumption
Charge voltage 'absorption'
Charge voltage 'equalization' 3)
Charge voltage 'float'
Charge algorithm
Temperature compensation
Protection
Operating temperature
Humidity
Maximum altitude
Environmental condition
Pollution degree
Data communication port
Colour
Power terminals
Protection category
Weight
Dimensions (h x w x d)
STANDARDS
Safety
1a) If more PV power is connected, the controller will limit input power.
1b) The PV voltage must exceed Vbat + 5V for the controller to start.
Thereafter the minimum PV voltage is Vbat + 1V.
2) A higher short circuit current may damage the controller in case of reverse polarity connection of
the PV array.
3) Default setting: OFF
MPPT 100/30
12/24V Auto Select
30A
440W
880W
100V
35A
98%
Default setting: 14,4V / 28,8V (adjustable)
Default setting: 16,2V / 28,8V (adjustable)
Default setting: 13,8V / 27,6V (adjustable)
multi-stage adaptive (eight preprogrammed algorithms)
or user defined algrithm
-16 mV / °C resp. -32 mV / °C
Battery reverse polarity (fuse, not user accessible)
PV reverse polarity, Output short circuit
Over temperature
-30 to +60°C (full rated output up to 40°C)
95%, non-condensing
5000m (full rated output up to 2000m)
Indoor type 1, unconditioned
VE.Direct (see the data communication white paper
on our website)
ENCLOSURE
Blue (RAL 5012)
13 mm² / AWG6
IP43 (electronic components), IP22
(connection area)
130 x 186 x 70 mm
EN/IEC 62109-1 / UL 1741 / CSA C22.2 NO.107.1-16
MPPT 100/50
50A
700W
1400W
100V
60A
98%
10 mA
PD3
1,3 kg