Proper Use, Device Description - ALFRA TML 90R Manual De Istrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Proper use
The permanent lifting magnet TML 90
according to its technical data and determination. Proper use includes adherence to the start-up, operating,
environment and maintenance conditions specified by the manufacturer. The user bears sole responsibility for
understanding the operating manual as well as for proper use and maintenance of the lifting magnet.
Device description
R
The TML 90
(Thin Material Lifter) magnet is a switchablelifting magnet with manual actuation designed to lift and
transport ferromagnetic materials. To activate the magnet, push the activation lever (A) into the ON position until it
audibly latches into place. The installed permanent magnet (B) generates a magnetic field in the lower magnetic
plate area (D). Owing to the special design of the TML 90
excellent adhesive force especially on thin materials of less than 10 mm.Care must be taken that the lever springs
back when working on thin materials. The activation lever must be lifted slightly at its end and returned by 60° into
the OFF positionto deactivate the magnet.
A rotatable and pivotable load swivel (C) is situated on the top of the lifting magnet. This load swivel can be used
with a soft eye to attach the lifting magnet to the hook of a crane.The load-bearing capacity of the lifting magnet is
equivalent to 1/3 of the maximum breakaway force of the magnet and thus complies with the standard safety
factor of 3:1.
Be sure to read the operation instructions completely before using this magnet for the first
time!
R
is designed to lift ferromagnetic, metallic loads and may only be used
R
, this magnetic field is very compact and develops
A) Activation lever
R
B) TMC 300
Magnetic base (41100.R)
C) Rotatable load swivel
D) Magnetic surface
15

Publicidad

Tabla de contenido
loading

Tabla de contenido