Technical data
Prod.-No.:
Designation:
Breakaway force:
Max. load-bearing capacity:
(on flat material
with safety factor 3:1)
Max. load-bearing capacity:
(at 6° inclination acc. to
EN 13155with safety factor 3:1)
Max. load-bearing capacity:
(at 90° inclination of the load
with safety factor 3:1)
Max. load-bearing capacity:
(on round pipes at 0° inclination)
Admissible diameter of round
pipes:
Dead weight of the unit:
Storage temperature:
Operating temperature:
Markings on theliftingmagnet
Detailed descriptions for the safe handling and proper operating conditions of the TML 90
sides and on top of the lifting magnet. This labeling must not be modified, damaged or removed. Otherwise the
manufacturer cannot be held responsible for any personal injuries, property damage or accidents resulting from this
fact. New labels must be ordered from the manufacturer if necessary.
Prod.-No.:189414233.R
Prod.-No.: 189414234.R
16
41100.L.R
R
TML 90
Lifting magnet
>270 kg from 6 mm S235
90 kg from 6 mm S235
81 kg from 6 mm S235
30 kg from 6 mm S235
20% - 50% of the load-bearing
capacity for flat material
25 – 200 mm
1,8 kg
-30°C to +60°C
-30°C to +60°C
>594lbs from 0.25"
200 lbsfrom 0,25"
178 lbs from 0,25"
66 lbsfrom0,25"
20% - 50% of the load-bearing
capacity for flat material
-22°F to+140°F
-22°F to+140°F
R
can be found on both
Prod.-No.:189414232.R
Prod.-No.: 189414237.R
1" – 8"
3,9lbs