13.7 Electrical connection

caso Vakuumierer MyVac 20
In order to ensure the safe and trouble-free operation of the
device, the following instructions must be observed for the
electrical connection:
• Before connecting the device, compare the connection data
(voltage and frequency) on the rating plate with those of your
electrical network. This data must agree in order that no
damages occur in the device.
If in doubt, ask your qualified electrician.
• The electrical outlet must be protected by a 16A safety cut-
out switch.
• The connection between the device and the electrical
network may employ a 3 meter long (max.) extension cable
with a cross-section of 1.5 mm². The use of multiple plugs or
gangs is prohibited because of the danger of fire that is
involved with this.
• Make sure that the power cable is undamaged and has not
been installed under the oven or over hot or sharp surfaces.
• The electrical safety of the device is only guaranteed if the
device is connected to a properly installed protective
conductor system. Operations using an electrical outlet
without a protective conductor are prohibited. If in doubt,
have the house installation checked over by a qualified
electrician.
The manufacturer cannot be made responsible for damages
that are caused by a missing or damaged protective
conductor.