TAB. 1 UP8 utility spring
L
(max)
4500
5000
1 RED + 1 GREEN
5500
6000(*)
1 RED + 1 GREEN
6500(*)
7000(*)
7500(*)
2 REDS + 1 GREEN
8000(*)
2 REDS + 1 GREEN
N.B.: Spring does not need to be changed even in the event of the mobile UPAM support being used (in this case, however, adjust load).x
When installing the high hip (CSO KA) refer to the UPGR barrier column for the choice of the spring.
(*) As concerns L≥ ≥ ≥ ≥ ≥ 6000, use the fixed UPAF support (or the mobile UPAM support).
UP8M = RED Spring with thread ∅ 7 (standard equipment includes: 1 RED spring + 1 GREEN spring)
Reversal of the direction of the rod
The UP4-Series barriers are normally supplied in the right-hand version. By right barrier we mean that the container
is assembled on the right, as seen from the side that can be inspected. To transform the barrier from right to left:
3.3 Disassemble the spring fixing parts (Fig. 8).
3.4 Rotate the lever arm 90° (fig. 8).
3.5 Release the springs and remove the springs securing elements and the springs themselves from the
opposite side (the upper spring [17] coupling and the transmission lever [15] have one screw in common).
3.6 Position the DIP2 on ON (fig. 10).
Installing the arm and accessories
3.7 Bring the rod bearing flange [11] to a vertical position. Lock the geared motor (see operating instruction).
3.8 Hook on the springs by means of the spring (fig. 7).
3.9 Install the rod and secure (fig. 4).
3.10 Release the geared motor and position the rod horizontally. Attention: The rod is not secured nor balanced.
3.11 Assemble any accessories (sensitive rubber profile, apron, container support, etc).
3.12 Spring balancing
N.B.: Spring loading must be made with the rod set vertically.
The UP8EL barrier is supplied complete with two springs: a green spring in Ø6 and a red spring in Ø7. See
table 1 to select the springs according to the net opening of the arm and the presence or absence of any
accessories. The springs are to be selected so that when the motor is released the arm is balanced in the center
(also with already installed accessories) or upwards (fig. 5).
The lever system which supports the springs for safety purposes is constructed in order to have a stable position
with arm completely open or completely closed, even with the motor release. Never use the motor force to
support the weight of the arm. Always use the balancing spring.
3.13 Adjusting the limit switch
Adjust, in observance of the sequence of operations:
-
Adjust the rod in the horizontal position (slightly upwards), mechanically operating the lever (fig.2 detail 15) in
order to make movement as smooth as possible.
-
Adjust the open/close end-of-travel pad (Fig. 6) in order to stop the motor 10-20 mm before it reaches the lock
(Fig. 2 detail 19).(*)
(*) with use the barrier recovers the clearance.
ATTENTION: The door of the barrier is impact resistant; it must always be mounted on the container
during the operation of the barrier.
4. ELECTRICAL CONNECTIONS AND STARTUP
The electrical connections and the startup of the UP8EL barrier are illustrated in the installation manual of the QE
Logic A21.
WARNING: set the RF force to the maximum level.
DITEC S.P.A - IP1513 UP8
UP8
L
1 GREEN
1 RED
2 REDS
2 REDS
UP8 + HIP BGO
L
1 RED
1 RED + 1 GREEN
1 RED + 1 GREEN
2 REDS
2 REDS
2 REDS + 1 GREEN
3 REDS
10
UP8 + UPGR
L
max 6 m
=
=
1 RED
1 RED + 1 GREEN
2 REDS
2 REDS
2 REDS + 1 GREEN
2 REDS + 1 GREEN
3 REDS