DITEC UP8EL Manual De Instalacion Y Manutencion página 11

Barrera electromecánica
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

5.
MAINTENANCE PROGRAM (each 6 months)
Power off 230 V~:
- Clean and oil the external levers and check that the visible nuts and screws are all well screwed down.
- Check the electrical connections.
- Check the manual release.
Power on 230 V~:
- Check the functioning of the limit switches.
- Check for proper functioning of the obstacle detector.
- Check the operation of all control and safety devices.
ATTENTION: For spare parts, see the spares price list.
Operating instruction UP8EL
Lock and release operations must be performed with motor not running.
It is recommended to keep outside barrier's operating range. The unlocked barrier may be subject
to independent movements.
RELEASE INSTRUCTION
In case of faulty operation or power failure, to unlock the barrier, open the door by means of the appropriate key and turn the
release lever antlclockwise. The barrier remains released. To lock, repeat the operation in reverse order.
GENERAL SAFETY PRECAUTIONS
The following precautions are an integral and essential part of the product and must be supplied to the user. Read them carefully as they
contain important indications for the safe installation, use and maintenace. These instruction must be kept and forwarded to all possible future user
of the system. This product must be used only for that which it has been expressely designed. Any other use is to be considered improper and
therefore dangerous. The manufacturer cannot be held responsible for possible damage caused by improper, erroneous or unresonable use. Avoid
operating in the proximity of the hinges or moving mechanical parts. Do not enter the field of action of the motorised door or gate while in motion. Do
not obstruct the motion of the motorised door or gate as this may cause a situation of danger. Do not lean against or hang on to the barrier when it
is moving. Do not allow children to play or stay within the field of action of the motorised door or gate. Keep remote control or any other control devices
out of the reach of children, in order to avoid possible involuntary activation of the motorised door or gate. In case of breack down or malfunctioning
of the product, disconnect from mains, do not attempt to repair or intervene directly and contact only qualified personnel. Failure to comply with the
above may create a situation of danger. All cleaning, maintenance or repair work must be carried out by qualified personnel.
In order to guarantee that the system works efficiently and correctly it is indispensable to comply with the manufacturer's indications thus having the
periodic maintenance of the motorised door or gate carried out by qualified personnel.
In particular regular checks are recommended in order to verify that the safety devices are operating correctly.
All installation, maintenance and repair work must be documented and made available to the user.