Menu stage 9: Operating modes
Push button
. "9" is displayed.
Menu Operating mode
value
0
Normal operation
(factory setting)
1
Normal operation with ventilation
position
The ventilation position can be initiated by
pressing the second push button on the
hand transmitter or via the signal 112
internal push button (accessory).
2
Partial opening of side sectional doors
Partial opening of approx. 1m can be
initiated by pressing the second push
button on the hand transmitter or via the
signal 112 internal push button
(accessory).
The 2nd push button of the
!
transmitter has to be teached-in again after
changing the operation mode 0, 1 and 2.
5
Opening-Closing operation
6
Automatic Closing
Set open phase in menu stage A.
7
Automatic Closing
Break of open phase via light barrier.
8
Automatic Closing
Break of open phase via impulse
generator.
Operation mode Automatic Closing (6, 7
and 8):
A light barrier has to be installed 13d.
Dear customer,
The product you have purchased has undergone
extensive testing throughout its manufacture to
ensure that it meets high standards in terms of both
quality and functionality.
If during the guarantee period the product becomes
unusable in whole or in part due to material or
manufacturing defects, we undertake, at our
discretion, to rectify the defects by repairing or
replacing the faulty product free of charge or granting
a reasonable price reduction.
This undertaking does not cover defects occurring as
a result of
- incorrect installation or connection
- faulty putting into service and operation
- improper or non-designated use or
maintenance
- repair by non-qualified persons
- normal wear and tear or
Retain these installation, operating and maintenance instructions for the full duration of the operator's service life!
Menu stage "A": Open phases of the door
Press button
. "A" is displayed. These phases can
only be set using the operation mode Automatic
Closing (6, 7 and 8).
Menu
Open phase
value
(without warning time 10 seconds)
0
0 s
1
10 s
2
30 s
3
60 s
4
90 s
5
120 s
6
150 s
7
180 s
8
210 s
9
240 s
Terms of the Guarantee
unauthorized modifications
- use of non-original components or removal of the
data plate
- mechanical damage (due to being dropped or
having sustained a serious impact)
- Acts of God und exceptional environmental
conditions (lightening strike, flooding etc.)
- negligent or wanton destruction
The guarantee does not cover components that are
subject to wear and tear or items that require
frequent replacement (e.g. light bulbs, batteries,
fuses).
Prerequisites for claiming under the guarantee
This guarantee is granted in addition to the sales
contract concluded with your dealer and does not
affect your statutory rights arising out of that sales
a lack of
contract.
The guarantee only covers defects occurring in the
product that forms the subject of the contract. We
shall not assume responsibility for follow-up costs
resulting from installation and dismantling, checking
of parts, freight costs and postal charges nor for
claims for compensation and lost profit.
At our request the parts involved shall be returned to
us free of charge and in the case of replacement
automatically become our property.
We grant the following guarantee:
2 years on the control unit's electronic components
2 years on remote controls and accessories
The guarantee comes into force on the day of
delivery. In order to claim under the guarantee, you
must furnish proof of purchase. Making a claim
under the guarantee does not extend the guarantee
period.
Repaired or replaced parts are guaranteed for 6
months, however, at least for the original guarantee
period.
GB