Rated data

Input data
Type
E94AZHN0026

Temperature in the control cabinet
Output data
Type
E94AZHN0026

Temperature in the control cabinet
Area
Input voltage
Output voltage
Brake current
Cable protection
Control input DI
Signalling output DO
Control voltage
Control current
Output 5 ... 50 mA
Protective function
Max. connectable cable
cross−section
Maximum cable length
EDK94AZHN26 DE/EN/FR/ES/IT 1.1
Voltage
[V]
400/500
Voltage
[V]
180/225
Values
AC 400 V (320 ... 550 V), 45 ... 65 Hz
DC 180 V
0.1 ... 0.61 A
Recommendation: 5 A, tripping characteristic "B" or "C"
DC 24 V, PLC level
HIGH
LOW
Input 5 ... 10 mA
Protected against polarity reversal up to DC 60 V
2
2.5 mm
AWG 12
150 m
l
Frequency
[Hz]
max. +45 °C
50/60
0.75/0.75
Frequency
[Hz]
max. +45 °C
0 (DC)
0.75/0.75
With mains voltage of AC 400 V
DC +15 ... 30 V
DC 0 ... +3 V
Technical data
Rated data
Current [A]
max. +55 °C


0.61/0.61
Current [A]
max. +55 °C


0.61/0.61
2
Number
of
phases
1
Number
of
phases
1
35