14.1
General technical data
Ambient temperature
(at rated values)
Permissible humidity
(at rated values)
Power derating
(currents and torques)
Ball-bearing life
Technical data for every motor type can be found in chapter "Technical Data" from p. 66.
14.2
Standard features
14.2.1
Style
The basic style for the VLM motors is style IM B5 according to EN 60034-7.
14.2.2
Flange
Flange dimensions to NEMA standard (NEMA ICS 16 Metric, NEMA ICS 19 Inch),
fit h7/ j6
Accuracy:
Shaft extension concentricity: 0,05 mm
Concentricity of the flange: 0,1 mm
Runout tolerances : 0,1 mm
Maximally permissible flange temperature in continuous operation: 65°C
Servomotors VLM
05/2016
5...+40°C for site altitude up to 1000m amsl
It is vital to consult our applications department for
ambient temperatures above 40°C and encapsulated
mounting of the motors.
95% rel. humidity, no condensation
1% / K in range 40°C...50°C up to 1000m amsl
for site altitude above 1000m amsl and 40°C
6%
up to 2000m amsl
17% up to 3000m amsl
30% up to 4000m amsl
55% up to 5000m amsl
No derating for site altitudes above 1000m amsl
with temperature reduction of 10K / 1000m
³ 20.000 operating hours
Technical Description